Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Electrolytes in sick neonates – which sodium is the right answer?
by
King, Richard I
, Lynn, Adrienne M
, Florkowski, Christopher M
, Mackay, Richard J
in
Blood
/ Blood Gas Analysis
/ Capillaries - physiology
/ Electrodes
/ Electrolytes
/ Electrolytes - blood
/ Humans
/ Hypoalbuminemia - epidemiology
/ Infant, Newborn
/ Ion-Selective Electrodes
/ Laboratories
/ Neonates
/ Patients
/ Plasma
/ Point-of-Care Systems
/ Quality control
/ Sodium
/ Sodium - blood
2013
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Electrolytes in sick neonates – which sodium is the right answer?
by
King, Richard I
, Lynn, Adrienne M
, Florkowski, Christopher M
, Mackay, Richard J
in
Blood
/ Blood Gas Analysis
/ Capillaries - physiology
/ Electrodes
/ Electrolytes
/ Electrolytes - blood
/ Humans
/ Hypoalbuminemia - epidemiology
/ Infant, Newborn
/ Ion-Selective Electrodes
/ Laboratories
/ Neonates
/ Patients
/ Plasma
/ Point-of-Care Systems
/ Quality control
/ Sodium
/ Sodium - blood
2013
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Electrolytes in sick neonates – which sodium is the right answer?
by
King, Richard I
, Lynn, Adrienne M
, Florkowski, Christopher M
, Mackay, Richard J
in
Blood
/ Blood Gas Analysis
/ Capillaries - physiology
/ Electrodes
/ Electrolytes
/ Electrolytes - blood
/ Humans
/ Hypoalbuminemia - epidemiology
/ Infant, Newborn
/ Ion-Selective Electrodes
/ Laboratories
/ Neonates
/ Patients
/ Plasma
/ Point-of-Care Systems
/ Quality control
/ Sodium
/ Sodium - blood
2013
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Electrolytes in sick neonates – which sodium is the right answer?
Journal Article
Electrolytes in sick neonates – which sodium is the right answer?
2013
Request Book From Autostore
and Choose the Collection Method
Overview
Introduction Hypoproteinaemia leads to spuriously high-sodium values when measured by indirect ion-selective electrodes (ISE) as used in main laboratory analysers compared with direct ISE employed in point-of-care analysers (POCT). The authors, therefore, investigated the occurrence of hypoalbuminaemia and its effect on measured sodium from POCT and the main laboratory analyser of neonatal intensive-care samples. Method Sodium, in paired retrospective samples, measured by the main laboratory and neonatal unit blood-gas (POCT) analysers were compared. Results Hypoalbuminaemia (<30 g/l) was present in 1400/2420 paired results. Sodium was higher when measured by laboratory analyser, the difference increased with decreasing albumin; sodium (laboratory – POCT)=7.6 (±1.1)–0.22 (±0.04)×albumin. A difference >3 mmol/l was present in 31% and consequently underestimated (9.4%) hyponatraemia and overestimated (3.8%) hypernatraemia. Conclusion Hypoalbuminaemia is common in sick neonates and monitoring electrolytes using POCT and laboratory analysers frequently yield significantly different results with consequent misclassification. In these patients, measurement of electrolytes by direct ISE (blood-gas analyser) may be more accurate.
This website uses cookies to ensure you get the best experience on our website.