Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Laboratory Intercomparison of Gene Expression Assays
by
Peinnequin, A.
, Faggioni, G.
, Braselmann, H.
, Lista, F.
, Zenhausern, F.
, Meineke, V.
, Greither, R.
, Bernard, N.
, Herodin, F.
, Rothkamm, K.
, Brengues, M.
, Terbrueggen, B.
, Beinke, C.
, Poyot, T.
, Badie, C.
, Missel, A.
, Kabacik, S.
, Balagurunathan, Y.
, Abend, M.
in
Adult
/ Biological Assay - methods
/ Blood
/ Calibration
/ Dose-Response Relationship, Radiation
/ Dosimetry
/ Electrophoresis, Capillary - methods
/ Estimate reliability
/ Gene expression
/ Gene Expression - radiation effects
/ Genes
/ Humans
/ Laboratory Proficiency Testing
/ Leukocytes - radiation effects
/ Leukocytes - ultrastructure
/ Lithium
/ Male
/ Microspheres
/ NATO BIODOSIMETRY STUDY
/ Nucleic Acid Amplification Techniques - methods
/ Radiation dosage
/ Radiation Injuries - diagnosis
/ Radiation Injuries - genetics
/ Radioactive Hazard Release
/ Radiometry - methods
/ Radiotherapy
/ Reproducibility of Results
/ Reverse Transcriptase Polymerase Chain Reaction - methods
/ RNA
/ Sensitivity and Specificity
/ Single-Blind Method
/ Time Factors
/ Triage
2013
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Laboratory Intercomparison of Gene Expression Assays
by
Peinnequin, A.
, Faggioni, G.
, Braselmann, H.
, Lista, F.
, Zenhausern, F.
, Meineke, V.
, Greither, R.
, Bernard, N.
, Herodin, F.
, Rothkamm, K.
, Brengues, M.
, Terbrueggen, B.
, Beinke, C.
, Poyot, T.
, Badie, C.
, Missel, A.
, Kabacik, S.
, Balagurunathan, Y.
, Abend, M.
in
Adult
/ Biological Assay - methods
/ Blood
/ Calibration
/ Dose-Response Relationship, Radiation
/ Dosimetry
/ Electrophoresis, Capillary - methods
/ Estimate reliability
/ Gene expression
/ Gene Expression - radiation effects
/ Genes
/ Humans
/ Laboratory Proficiency Testing
/ Leukocytes - radiation effects
/ Leukocytes - ultrastructure
/ Lithium
/ Male
/ Microspheres
/ NATO BIODOSIMETRY STUDY
/ Nucleic Acid Amplification Techniques - methods
/ Radiation dosage
/ Radiation Injuries - diagnosis
/ Radiation Injuries - genetics
/ Radioactive Hazard Release
/ Radiometry - methods
/ Radiotherapy
/ Reproducibility of Results
/ Reverse Transcriptase Polymerase Chain Reaction - methods
/ RNA
/ Sensitivity and Specificity
/ Single-Blind Method
/ Time Factors
/ Triage
2013
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Laboratory Intercomparison of Gene Expression Assays
by
Peinnequin, A.
, Faggioni, G.
, Braselmann, H.
, Lista, F.
, Zenhausern, F.
, Meineke, V.
, Greither, R.
, Bernard, N.
, Herodin, F.
, Rothkamm, K.
, Brengues, M.
, Terbrueggen, B.
, Beinke, C.
, Poyot, T.
, Badie, C.
, Missel, A.
, Kabacik, S.
, Balagurunathan, Y.
, Abend, M.
in
Adult
/ Biological Assay - methods
/ Blood
/ Calibration
/ Dose-Response Relationship, Radiation
/ Dosimetry
/ Electrophoresis, Capillary - methods
/ Estimate reliability
/ Gene expression
/ Gene Expression - radiation effects
/ Genes
/ Humans
/ Laboratory Proficiency Testing
/ Leukocytes - radiation effects
/ Leukocytes - ultrastructure
/ Lithium
/ Male
/ Microspheres
/ NATO BIODOSIMETRY STUDY
/ Nucleic Acid Amplification Techniques - methods
/ Radiation dosage
/ Radiation Injuries - diagnosis
/ Radiation Injuries - genetics
/ Radioactive Hazard Release
/ Radiometry - methods
/ Radiotherapy
/ Reproducibility of Results
/ Reverse Transcriptase Polymerase Chain Reaction - methods
/ RNA
/ Sensitivity and Specificity
/ Single-Blind Method
/ Time Factors
/ Triage
2013
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Laboratory Intercomparison of Gene Expression Assays
2013
Request Book From Autostore
and Choose the Collection Method
Overview
The possibility of a large-scale acute radiation exposure necessitates the development of new methods that could provide rapid individual dose estimates with high sample throughput. The focus of the study was an intercomparison of laboratories' dose-assessment performances using gene expression assays. Lithium-heparinized whole blood from one healthy donor was irradiated (240 kVp, 1 Gy/min) immediately after venipuncture at approximately 37°C using single X-ray doses. Blood samples to establish calibration curves (0.25–4 Gy) as well as 10 blinded test samples (0.1–6.4 Gy) were incubated for 24 h at 37°C supplemented with an equal volume of medium and 10% fetal calf serum. For quantitative reverse transcription polymerase chain reaction (qRT-PCR), samples were lysed, stored at −20°C and shipped on ice. For the Chemical Ligation Dependent Probe Amplification methodology (CLPA), aliquots were incubated in 2 ml CLPA reaction buffer (DxTerity), mixed and shipped at room temperature. Assays were run in each laboratory according to locally established protocols. The mean absolute difference (MAD) of estimated doses relative to the true doses (in Gy) was calculated. We also merged doses into binary categories reflecting aspects of clinical/diagnostic relevance and examined accuracy, sensitivity and specificity. The earliest reported time on dose estimates was <8 h. The standard deviation of technical replicate measurements in 75% of all measurements was below 11%. MAD values of 0.3–0.5 Gy and 0.8–1.3 Gy divided the laboratories contributions into two groups. These fourfold differences in accuracy could be primarily explained by unexpected variances of the housekeeping gene (P = 0.0008) and performance differences in processing of calibration and blinded test samples by half of the contributing laboratories. Reported gene expression dose estimates aggregated into binary categories in general showed an accuracies and sensitivities of 93–100% and 76–100% for the groups, with low MAD and high MAD, respectively. In conclusion, gene expression-based dose estimates were reported quickly, and for laboratories with MAD between 0.3–0.5 Gy binary dose categories of clinical significance could be discriminated with an accuracy and sensitivity comparable to established cytogenetic assays.
Publisher
The Radiation Research Society,Radiation Research Society,Allen Press Inc
Subject
/ Blood
/ Dose-Response Relationship, Radiation
/ Electrophoresis, Capillary - methods
/ Gene Expression - radiation effects
/ Genes
/ Humans
/ Laboratory Proficiency Testing
/ Leukocytes - radiation effects
/ Lithium
/ Male
/ Nucleic Acid Amplification Techniques - methods
/ Radiation Injuries - diagnosis
/ Radiation Injuries - genetics
/ Reverse Transcriptase Polymerase Chain Reaction - methods
/ RNA
/ Triage
This website uses cookies to ensure you get the best experience on our website.