MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx
Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx
Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx
Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx
Journal Article

Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx

2019
Request Book From Autostore and Choose the Collection Method
Overview
BackgroundInitial clinical experience with Squid shows subjectively reduced artifacts on post-embolization CT scans compared with Onyx. To further investigate these observations, we aimed to perform a comparison of artifacts between Squid and Onyx in a controlled in vitro model.Materials and methodsOnyx 18 and all four variants of Squid (Squid 18, Squid 18 low density (LD), Squid 12, Squid 12 LD) were each injected in dimethylsulfoxide (DMSO) compatible test tubes. The tubes containing precipitated embolic material were inserted in a CT phantom for conventional and flat panel CT acquisitions. Beam hardening artifacts were quantified using objective and subjective measurements.ResultsObjective evaluation of artifacts within regions of interest (ROIs) placed around the embolic material on CT and flat panel CT images demonstrated significantly lower noise and Hounsfield unit (HU) range values for all four Squid products compared with Onyx 18. On both CT and flat panel CT, LD variants of Squid 18 and Squid 12 had significantly lower noise and HU range values than their normal density counterparts on longitudinal ROIs. When using subjective measures for diagnostic value within ROIs placed around the embolic material on both CT and flat panel CT images, the number of non-diagnostic ROIs was significantly higher for Onyx 18 than for all four Squid variants.ConclusionAll four variants of Squid induced fewer beam hardening artifacts than Onyx 18 on CT and flat panel CT acquisitions. LD variants of Squid induced fewer artifacts than their normal density counterparts.