Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study
by
Coon, Alexander L
, Cekirge, Saru
, Delgado Almandoz, Josser E
, Baltacioglu, Feyyaz
, Molyneux, Andy
, Szikora, Istvan
, Hoit, Daniel
, Byrne, James V
, Arthur, Adam S
, Elijovich, Lucas
, Sultan, Ali
, Saatci, Isil
, Fiorella, David
in
Aneurysms
/ Braided composites
/ Laboratories
/ New Devices and Techniques
/ Patients
/ Pipelines
/ Stroke
/ Systematic review
/ Transplants & implants
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study
by
Coon, Alexander L
, Cekirge, Saru
, Delgado Almandoz, Josser E
, Baltacioglu, Feyyaz
, Molyneux, Andy
, Szikora, Istvan
, Hoit, Daniel
, Byrne, James V
, Arthur, Adam S
, Elijovich, Lucas
, Sultan, Ali
, Saatci, Isil
, Fiorella, David
in
Aneurysms
/ Braided composites
/ Laboratories
/ New Devices and Techniques
/ Patients
/ Pipelines
/ Stroke
/ Systematic review
/ Transplants & implants
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study
by
Coon, Alexander L
, Cekirge, Saru
, Delgado Almandoz, Josser E
, Baltacioglu, Feyyaz
, Molyneux, Andy
, Szikora, Istvan
, Hoit, Daniel
, Byrne, James V
, Arthur, Adam S
, Elijovich, Lucas
, Sultan, Ali
, Saatci, Isil
, Fiorella, David
in
Aneurysms
/ Braided composites
/ Laboratories
/ New Devices and Techniques
/ Patients
/ Pipelines
/ Stroke
/ Systematic review
/ Transplants & implants
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study
Journal Article
The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study
2019
Request Book From Autostore
and Choose the Collection Method
Overview
IntroductionThe Woven EndoBridge Intrasaccular Therapy (WEB-IT) Study is a pivotal, prospective, single-arm, investigational device exemption study designed to evaluate the safety and effectiveness of the WEB device for the treatment of wide-neck bifurcation aneurysms.MethodsOne-hundred and fifty patients with wide-neck bifurcation aneurysms were enrolled at 21 US and six international centers. Angiograms from the index procedure, and 6-month and 1-year follow-up visits were all reviewed by a core laboratory. All adverse events were reviewed and adjudicated by a clinical events adjudicator. A data monitoring committee provided oversight during the trial to ensure subject safety.ResultsOne-hundred and forty-eight patients received the WEB implant. One (0.7%) primary safety event occurred during the study—a delayed ipsilateral parenchymal hemorrhage—on postoperative day 22. No primary safety events occurred after 30 days through 1 year. At the 12-month angiographic follow-up, 77/143 patients (53.8%) had complete aneurysm occlusion. Adequate occlusion was achieved in 121/143 (84.6%) subjects.ConclusionsThe prespecified safety and effectiveness endpoints for the aneurysms studied in the WEB-IT trial were met. The results of this trial suggest that the WEB device provides an option for patients with wide-neck bifurcation aneurysms that is as effective as currently available therapies and markedly safer.Trial registration number NCT02191618
Publisher
BMJ Publishing Group LTD,BMJ Publishing Group
Subject
This website uses cookies to ensure you get the best experience on our website.