Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Harmonization of amyloid PET radiotracers using ComBat and its influence on detecting treatment effects in a simulated clinical trial
by
Gordon, Brian A.
, Yang, Braden
, Earnest, Tom
, Sotiras, Aristeidis
, Kumar, Sayantan
in
Biomarkers
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Harmonization of amyloid PET radiotracers using ComBat and its influence on detecting treatment effects in a simulated clinical trial
by
Gordon, Brian A.
, Yang, Braden
, Earnest, Tom
, Sotiras, Aristeidis
, Kumar, Sayantan
in
Biomarkers
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Harmonization of amyloid PET radiotracers using ComBat and its influence on detecting treatment effects in a simulated clinical trial
Journal Article
Harmonization of amyloid PET radiotracers using ComBat and its influence on detecting treatment effects in a simulated clinical trial
2024
Request Book From Autostore
and Choose the Collection Method
Overview
Background Differences in amyloid PET radiotracer pharmacokinetics and binding properties lead to discrepancies in amyloid uptake measurements, which may adversely affect the statistical power of clinical trials that utilize multiple tracers to track brain amyloid deposition. To address this, Centiloid was developed for standardizing global amyloid SUVRs across tracers to a common scale. Alternatively, ComBat is a technique for harmonizing batch effects while preserving variations from biologically‐relevant covariates. Unlike Centiloid, ComBat is entirely data‐driven, does not require a calibration process, and can be applied to regional SUVRs. However, it has not been validated for amyloid PET. Here, we evaluate whether ComBat improves detection of treatment effects in a simulated clinical trial. Method 365 amyloid‐positive subjects were identified from the OASIS‐3 dataset, from which 322 Pittsburgh compound B (PiB) and 260 18F‐Florbetapir (FBP) PET scans were selected. SUVRs of the global cortical region and 82 FreeSurfer regions were computed from each scan using the PET Unified Pipeline. Linear mixed effects (LME) models were fitted on each tracer separately and used to simulate longitudinal SUVRs of placebo and treatment groups in a hypothetical clinical trial (Figure 1). A negative rate‐of‐change was introduced to the treatment group to mimic a treatment effect. Additionally, tracer mixing proportions were varied within each group. Centiloid and ComBat were applied to simulated data to harmonize across tracers. A separate LME model was fitted to test for significant differences in SUVR rate‐of‐change between groups. Power was estimated as the proportion of significant findings across 1000 simulations. Result After harmonization with either Centiloid or ComBat with no covariates, an increase in power was observed in the presence of a treatment effect, and a decrease in Type‐I error was observed for no treatment effect (Figure 2). These changes were most prominent in cases where groups exhibited differing tracer mixing proportions. Similar patterns were observed for regional SUVRs (Figure 3). Conclusion We demonstrated that tracer harmonization is important for improving power in the presence of a treatment effect and reducing Type‐I error in its absence. ComBat performs comparably to Centiloid in harmonizing amyloid radiotracers in the context of a clinical trial.
Publisher
John Wiley and Sons Inc
Subject
MBRLCatalogueRelatedBooks
This website uses cookies to ensure you get the best experience on our website.