Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Sputum Rheology Changes in Cystic Fibrosis Lung Disease Following Two Different Types of Physiotherapy
by
Kieselmann, Rita
, Reinhardt, Dietrich
, Lindemann, Hermann
, Brand, Peter
, App, Ernst M.
, King, Malcolm
, Dasgupta, Bonnie
in
autogenic drainage
/ cystic fibrosis
/ Flutter
/ mucus clearance
/ mucus viscoelasticity
/ physiotherapy
/ pulmonary function
1998
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Sputum Rheology Changes in Cystic Fibrosis Lung Disease Following Two Different Types of Physiotherapy
by
Kieselmann, Rita
, Reinhardt, Dietrich
, Lindemann, Hermann
, Brand, Peter
, App, Ernst M.
, King, Malcolm
, Dasgupta, Bonnie
in
autogenic drainage
/ cystic fibrosis
/ Flutter
/ mucus clearance
/ mucus viscoelasticity
/ physiotherapy
/ pulmonary function
1998
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Sputum Rheology Changes in Cystic Fibrosis Lung Disease Following Two Different Types of Physiotherapy
by
Kieselmann, Rita
, Reinhardt, Dietrich
, Lindemann, Hermann
, Brand, Peter
, App, Ernst M.
, King, Malcolm
, Dasgupta, Bonnie
in
autogenic drainage
/ cystic fibrosis
/ Flutter
/ mucus clearance
/ mucus viscoelasticity
/ physiotherapy
/ pulmonary function
1998
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Sputum Rheology Changes in Cystic Fibrosis Lung Disease Following Two Different Types of Physiotherapy
Journal Article
Sputum Rheology Changes in Cystic Fibrosis Lung Disease Following Two Different Types of Physiotherapy
1998
Request Book From Autostore
and Choose the Collection Method
Overview
The aim of the present study was to investigate the efficacy of two frequently used physiotherapies (PTs) for the removal of bronchial secretions in cystic fibrosis (CF) lung disease: autogenic drainage (AD) and the Flutter (Desitin in Germany). AD is believed to improve mucus clearance from peripheral to central airways due to airway caliber changes in combination with a special breathing technique. The Flutter is an easy-to-use physiotherapy device based on oscillations of a steel ball during expiration through a pipe-type device.
To evaluate the acute and chronic physiotherapy effects of these two techniques, 14 CF patients underwent either twice daily AD or Flutter treatment for 4 consecutive weeks in a randomized crossover design. Prior to each therapy interval, for a 1-week wash-out period, no PT was administered, but patients continued regular medication. At the beginning and end of each 4-week interval, pulmonary function was measured before and after an acute 30-min therapy. At the end of the PT session, sputum was collected, weighed, and deep frozen until analyzed. The viscoelasticity of the sputum was evaluated using a magnetic microrheometer.
No significant changes were noted for FVC, FEV1, or sputum volume throughout the study. Sputum viscoelasticity (rigidity index), however, was significantly lower (p<0.01) after therapy with the Flutter in comparison with AD, predicting improvements in mucociliary and cough clearability of the secretions. In a companion in vitro experiment, oscillations generated by passing humidified air over CF sputum lining an acrylic tube connected to a Flutter device were found to decrease sputum elasticity, as measured by a filancemeter. These findings suggest that applied oscillations are capable of decreasing mucus viscoelasticity within the airways at frequencies and amplitudes achievable with the Flutter device, and provide direct evidence that PT can reduce the viscoelasticity of sputum.
Publisher
Elsevier Inc,American College of Chest Physicians
This website uses cookies to ensure you get the best experience on our website.