Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Twenty-Seven-Gauge Vitrectomy
by
de Oliveira, Paulo Ricardo Chaves
, Chow, David Robert
in
Design
/ Diabetes
/ Diabetic retinopathy
/ Efficiency
/ Fluid dynamics
/ Light
/ Medicine
/ Medicine & Public Health
/ Ocular Infections (B Jeng and L Schocket
/ Ophthalmology
/ Section Editors
/ Surgeons
/ Surgery
/ Topical Collection on Ocular Infections
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Twenty-Seven-Gauge Vitrectomy
by
de Oliveira, Paulo Ricardo Chaves
, Chow, David Robert
in
Design
/ Diabetes
/ Diabetic retinopathy
/ Efficiency
/ Fluid dynamics
/ Light
/ Medicine
/ Medicine & Public Health
/ Ocular Infections (B Jeng and L Schocket
/ Ophthalmology
/ Section Editors
/ Surgeons
/ Surgery
/ Topical Collection on Ocular Infections
2017
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Twenty-Seven-Gauge Vitrectomy
by
de Oliveira, Paulo Ricardo Chaves
, Chow, David Robert
in
Design
/ Diabetes
/ Diabetic retinopathy
/ Efficiency
/ Fluid dynamics
/ Light
/ Medicine
/ Medicine & Public Health
/ Ocular Infections (B Jeng and L Schocket
/ Ophthalmology
/ Section Editors
/ Surgeons
/ Surgery
/ Topical Collection on Ocular Infections
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Twenty-Seven-Gauge Vitrectomy
2017
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose of Review
This paper aims to provide an overview of the currents aspects involving 27-gauge vitrectomy published on the PubMed directory.
Recent Findings
Almost 15 years have passed since the microincision vitrectomy system was introduced. The idea of removing vitreous through a smaller aperture has become a reality and is widely adopted among surgeons. Although not completely accepted, the use of 27-gauge systems has shown encouraging results. Newer vitrectomy platforms and cutter designs have tried to associate high-performance, smaller instruments with better outcomes. Consequently, the indications for 27-gauge vitrectomy have broadened during the last few years.
Summary
Twenty-seven-gauge vitrectomy seems to be safe and feasible in a variety of vitreoretinal scenarios.