MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems
Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems
Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems
Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems
Journal Article

Integrated Seismic and Energy Retrofitting of Masonry Elements Strengthened with PCM-enhanced GTRM/FRCM systems

2024
Request Book From Autostore and Choose the Collection Method
Overview
The integration/combination of seismic and energy retrofit measures has been a subject of study for the past decade, exhibiting promising prospects. The main objective of these interventions is to mitigate seismic vulnerability while concurrently enhancing the energy performance and efficiency of new and existing buildings. Integrated approaches can hold the potential for substantial cost savings, time efficiency, and minimal disruption to occupants. The current body of literature emphasizes exploring the benefits of incorporating innovative methods/materials into conventional uncoupled retrofit initiatives. This study focuses on evaluating integrated measures at the panel scale for the prevalent Unreinforced Masonry (URM) typologies in Italy. A design framework has been introduced, aimed at enhancing the seismic capacity of buildings while concurrently improving energy efficiency through the integration of new materials (e.g., highly latent thermal energy storage systems achieved through the integration of Phase Change Materials - PCMs) into retrofit materials. To assess the reduction of the seismic vulnerability, the improvement of the shear strength is estimated by modifying the failure domains, while energy efficiency and thermal-energy storage enhancements are evaluated by using enthalpy-based theories, implemented into open-source software (i.e., FEM-based and through EnergyPlus). Thus, the design variables are those defined by the URM typologies, the adopted retrofitting technique, and the considered envelope. The adopted integrated (seismic and energy retrofitting) solutions will be compared with the standard reference one in terms of the energy consumed by the enclosed building to keep the indoor thermal comfort which also guarantees the target level of structural performance.