Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Ask George
in
Biomedical Engineering - standards
/ Equipment and Supplies - standards
/ Equipment Failure Analysis - standards
/ Guideline Adherence - organization & administration
/ Joint Commission on Accreditation of Healthcare Organizations - organization & administration
/ Maintenance and Engineering, Hospital - organization & administration
/ Maintenance management
/ Preventive maintenance
/ Repair & maintenance
/ Risk assessment
/ United States
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Ask George
by
in
Biomedical Engineering - standards
/ Equipment and Supplies - standards
/ Equipment Failure Analysis - standards
/ Guideline Adherence - organization & administration
/ Joint Commission on Accreditation of Healthcare Organizations - organization & administration
/ Maintenance and Engineering, Hospital - organization & administration
/ Maintenance management
/ Preventive maintenance
/ Repair & maintenance
/ Risk assessment
/ United States
2017
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Ask George
in
Biomedical Engineering - standards
/ Equipment and Supplies - standards
/ Equipment Failure Analysis - standards
/ Guideline Adherence - organization & administration
/ Joint Commission on Accreditation of Healthcare Organizations - organization & administration
/ Maintenance and Engineering, Hospital - organization & administration
/ Maintenance management
/ Preventive maintenance
/ Repair & maintenance
/ Risk assessment
/ United States
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Ask George
2017
Request Book From Autostore
and Choose the Collection Method
Overview
Several questions on alternative equipment maintenance (AEM) plan are answered. If your risk assessment results in placing certain equipment in an AEM, you may change either the manufacturer's scheduled maintenance activities or frequencies (or both) as long as your risk assessment indicates that these changes do not reduce the safety of equipment and that the changes are based on accepted standards of practice. Changes like this should only be made with corresponding changes in hospital policy. Hospitals should also have (and follow) robust policies that address how to capture equipment that was unavailable (\"in use\" or \"non-locatable\") during its scheduled maintenance window. The Joint Commission and Centers for Medicare & Medicaid Services allow hospitals to consider documented service histories from sources other than the hospital when conducting the risk assessment to determine what equipment to be included in an AEM.
Publisher
Association for the Advancement of Medical Instrumentation, AAMI
Subject
Biomedical Engineering - standards
/ Equipment and Supplies - standards
/ Equipment Failure Analysis - standards
/ Guideline Adherence - organization & administration
/ Joint Commission on Accreditation of Healthcare Organizations - organization & administration
/ Maintenance and Engineering, Hospital - organization & administration
This website uses cookies to ensure you get the best experience on our website.