Investigation on the occupant behaviors of split air conditioners in public institutions in china
by
Wang, Yongzhao
, Feng, Ye
, Cheng, Lang
, Wang, Jun
, Ba, Yunlin
in
Air conditioners
/ Normal distribution
/ Residential buildings
/ Statistical analysis
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Investigation on the occupant behaviors of split air conditioners in public institutions in china
by
Wang, Yongzhao
, Feng, Ye
, Cheng, Lang
, Wang, Jun
, Ba, Yunlin
in
Air conditioners
/ Normal distribution
/ Residential buildings
/ Statistical analysis
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Investigation on the occupant behaviors of split air conditioners in public institutions in china
Journal Article
Investigation on the occupant behaviors of split air conditioners in public institutions in china
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Split air conditioners are widely utilized in public institutions. However, due to the high degree of randomness in occupant behaviors, formulating efficient energy-saving control strategies has proven to be challenging. To address this problem, this study investigated the occupant behaviors related to split air conditioners in public institutions in China, aiming to offer technical support for energy-saving control. First, the tolerance temperature range of occupants in the public institution was determined. The lower tolerance temperature limit was found to be 28 °C, and the upper limit was 30.5 °C. A comparative analysis revealed that the tolerance temperature range in the public institution is narrower than that in residential buildings. Statistical results indicated that the turn-on and adjustment operations of split air conditioners in the public institution exhibit distinct periodicity and fluctuations, with a significant lag of approximately 30 minutes. When adjusting the indoor temperature in the public institution, the temperature set point approximately follows a normal distribution. Most of the temperature set points are concentrated in the range of 23 °C to 28 °C, with a relatively small temperature regulation difference.