MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Comparative Study of MRI coils Design for MRI Imaging System
Comparative Study of MRI coils Design for MRI Imaging System
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparative Study of MRI coils Design for MRI Imaging System
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparative Study of MRI coils Design for MRI Imaging System
Comparative Study of MRI coils Design for MRI Imaging System

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparative Study of MRI coils Design for MRI Imaging System
Comparative Study of MRI coils Design for MRI Imaging System
Journal Article

Comparative Study of MRI coils Design for MRI Imaging System

2025
Request Book From Autostore and Choose the Collection Method
Overview
In this article, we survey a complete MRI systematic pipeline from theoretical modelling and numerical simulations to analysis and optimization of three different types of MRI coils. After a preliminary parametric exploration using generic models based on standard equations, a Method of Moments (MoM) study of geometrically representative coil structures was conducted to explore the nearer field effects. Then, Finite Difference Time Domain (FDTD) analysis was performed to realize the optimized-designed devices to be fabricated using MEMS process and confirmed its performance by using Vector Network Analyzer (VNA) and an anechoic chamber measurement. Performance comparisons based on parameters like resonance frequency, gain and radiated power were performed. Then for the Roger’s 6010TM RT/Duroid substrate material (ε=10.5) thickness 1.6 mm, the rectangular resonance frequency and return loss for the MRI coil are 8.06 GHz and 52.73 dB respectively. The gain on this coil is 36.45 dBm and the radiated powers were 59.25 dBi and 53.56 dBi. In comparison, using similar substrate material, it obtained a return loss of 52.73 dB and a gain of 45.89 dBm, while the circular MRI coil works at the same resonance frequency and could be found in the literature. Using Teflon-PTFE substrate with dielectric constant of 2.1, the resultant triangular MRI coil is fabricated which shows resonance frequency of 8 GHz return loss of 45.81 dB and gains of 49.35 dBm. This study’s performance metrics are closure with regularization results, and the closure is the validation of the enhanced performance of the proposed resonators for medical imaging applications. The designs were also extrapolated to bio-phantom models for further exploration. These RF coils could improve MRI diagnostic technologies as confirmed by the electromagnetic simulation results.