Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Effect of Sampling Frequency on a Unilateral Isometric Hamstring Strength Assessment Using Force Plates
by
Ripley, Nicholas J
, Comfort, P
, McMahon, J. J.
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Effect of Sampling Frequency on a Unilateral Isometric Hamstring Strength Assessment Using Force Plates
by
Ripley, Nicholas J
, Comfort, P
, McMahon, J. J.
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Effect of Sampling Frequency on a Unilateral Isometric Hamstring Strength Assessment Using Force Plates
Journal Article
Effect of Sampling Frequency on a Unilateral Isometric Hamstring Strength Assessment Using Force Plates
2024
Request Book From Autostore
and Choose the Collection Method
Overview
The purpose of this study was to determine the effect of sampling frequency on the 90–90° (90-degrees hip and knee flexion) isometric hamstring assessment. Thirty-three elite female soccer players (age: 18.7 ± 3.7 years; height: 158.3 ± 5.9 cm; body mass: 62.8 ± 5.5 kg) performed three unilateral trials on a single occasion of the 90–90° isometric hamstring assessment. Force-time data were collected using force plates at 1000 Hz and down sampled to 500-, 250-, and 100 Hz. Peak force (N), force (N) at 100- and 200 ms and average rate of force development (aRFD) (N/s) over a 100- and 200 ms epoch were calculated. A repeated measures of analysis of variance and effect size was used to compare means. Excellent absolute and good relative reliability was observed for peak force across all sampling frequencies. Force at 100- and 200 ms and aRFD over 100 ms and 200 ms resulted poor-moderate relative reliability and poor-excellent absolute reliability. No significant trivial differences were observed for peak force between sampling frequencies ( P > 0.05, Cohen’s d = 0.02–0.12). A significant difference ( P < 0.001) was identified in 500, 250 and 100 Hz, with small-moderate and small-large increases in force at set time points and aRFD, respectively, in comparison to 1000 Hz ( d = 0.21–2.00). Higher sampling frequencies (> 500 Hz) reduces the reliability of time dependent force characteristics, with minimal effect on peak force. Regular monitoring of peak force can be performed with higher sampling frequencies, but lower sampling frequencies would be beneficial to collect reliable rapid-force generating measures.
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.