Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Anchorage of Large-Diameter Reinforcing Bars in Ducts
by
Eberhard, Marc O
, Steuck, Kyle P
, Stanton, John F
in
Concrete
/ Ductwork
/ Fibers
/ Precast concrete
2009
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Anchorage of Large-Diameter Reinforcing Bars in Ducts
by
Eberhard, Marc O
, Steuck, Kyle P
, Stanton, John F
in
Concrete
/ Ductwork
/ Fibers
/ Precast concrete
2009
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Anchorage of Large-Diameter Reinforcing Bars in Ducts
2009
Request Book From Autostore
and Choose the Collection Method
Overview
In precast concrete systems, connections are often made by grouting bars that project from one member into ducts embedded in another. For bridge bents, bar-duct systems can be assembled rapidly if a few large bars and ducts are used to connect the column and cap beam. In some cases, the required anchorage lengths for the large bars exceed the length available. To evaluate the anchorage requirements for this situation, 14 pullout tests were performed on bars with sizes up to No. 18. The tests and a nonlinear finite element model showed that, under conditions similar to those tested, large bars can develop their yield and fracture strengths in as few as six and 10 bar diameters, respectively. The effects of the bar size were found to be small compared to the scatter among the test results. Parallel tests with polypropylene fibers showed that fibers generally decreased pullout resistance, although this is likely the result of reduced grout strength. [PUBLICATION ABSTRACT]
Publisher
American Concrete Institute
Subject
This website uses cookies to ensure you get the best experience on our website.