Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Validation of Up‐the‐Ramp Sampling with Cosmic‐Ray Rejection on Infrared Detectors
by
Rauscher, B. J.
, Mather, J. C.
, McKelvey, M. E.
, Offenberg, J. D.
, Stockman, H. S.
, Nieto‐Santisteban, M. A.
, Sengupta, R.
, Fixsen, D. J.
, Forrest, W. J.
, McMurray, Jr, R. E.
, Pipher, J. L.
, Hanisch, R. J.
in
Cosmic rays
/ Data processing
/ Datasets
/ Outliers
/ Pixels
/ Protons
/ Radiation detectors
/ Signal detection
/ Signal noise
/ Statistical median
2001
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Validation of Up‐the‐Ramp Sampling with Cosmic‐Ray Rejection on Infrared Detectors
by
Rauscher, B. J.
, Mather, J. C.
, McKelvey, M. E.
, Offenberg, J. D.
, Stockman, H. S.
, Nieto‐Santisteban, M. A.
, Sengupta, R.
, Fixsen, D. J.
, Forrest, W. J.
, McMurray, Jr, R. E.
, Pipher, J. L.
, Hanisch, R. J.
in
Cosmic rays
/ Data processing
/ Datasets
/ Outliers
/ Pixels
/ Protons
/ Radiation detectors
/ Signal detection
/ Signal noise
/ Statistical median
2001
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Validation of Up‐the‐Ramp Sampling with Cosmic‐Ray Rejection on Infrared Detectors
by
Rauscher, B. J.
, Mather, J. C.
, McKelvey, M. E.
, Offenberg, J. D.
, Stockman, H. S.
, Nieto‐Santisteban, M. A.
, Sengupta, R.
, Fixsen, D. J.
, Forrest, W. J.
, McMurray, Jr, R. E.
, Pipher, J. L.
, Hanisch, R. J.
in
Cosmic rays
/ Data processing
/ Datasets
/ Outliers
/ Pixels
/ Protons
/ Radiation detectors
/ Signal detection
/ Signal noise
/ Statistical median
2001
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Validation of Up‐the‐Ramp Sampling with Cosmic‐Ray Rejection on Infrared Detectors
Journal Article
Validation of Up‐the‐Ramp Sampling with Cosmic‐Ray Rejection on Infrared Detectors
2001
Request Book From Autostore
and Choose the Collection Method
Overview
We examine cosmic‐ray rejection methodology on data collected from InSb and Si:As detectors. The application of an up‐the‐ramp sampling technique with cosmic‐ray identification and mitigation is the focus of this study. This technique is valuable for space‐based observatories which are exposed to high‐radiation environments. We validate the up‐the‐ramp approach on radiation‐test data sets with InSb and Si:As detectors which were generated for SIRTF. The up‐the‐ramp sampling method studied in this paper is over 99.9% effective at removing cosmic rays and preserves the structure and photometric quality of the image to well within the measurement error.
Publisher
The University of Chicago Press
Subject
This website uses cookies to ensure you get the best experience on our website.