Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Analysis of power frequency electric field distortion caused by substation inspection robot
by
Yang, Hao
, Dou, Dandan
, Gong, Quanquan
, Yang, Fan
, Li, Yunqi
, Yang, Zhongju
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Analysis of power frequency electric field distortion caused by substation inspection robot
by
Yang, Hao
, Dou, Dandan
, Gong, Quanquan
, Yang, Fan
, Li, Yunqi
, Yang, Zhongju
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Analysis of power frequency electric field distortion caused by substation inspection robot
Journal Article
Analysis of power frequency electric field distortion caused by substation inspection robot
2021
Request Book From Autostore
and Choose the Collection Method
Overview
In the era of intellectualization, many substation inspection robots are being put into operation, but they will cause electric field distortion in the surrounding space during operation. This paper establishes a three-dimensional simplified simulation calculation model for 500kV substations and inspection robots. Based on the boundary element method, we simulate the power frequency electric field of the substation switchyard and analysis the distortion electric field when the inspection robot is in the station. The results show that when the electric field intensity is strong, the distortion coefficient caused by the robot will be larger, and the maximum can reach 2.25 times, and when the electric field intensity is small, the distortion coefficient will be smaller, and the distortion coefficient is 1.42 times on average.