Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Electrochemical and In Vitro Biological Evaluation of Bio-Active Coatings Deposited by Magnetron Sputtering onto Biocompatible Mg-0.8Ca Alloy
by
Antoniac, Aurora
, Forna, Norin
, Antoniac, Iulian
, Bița, Ana-Iulia
, Stan, George E.
, Miculescu, Marian
, Constantin, Bujor
, Leonat, Lucia
in
Alloys
/ Biocompatibility
/ Biodegradability
/ Biodegradable materials
/ Biodegradation
/ Biomedical materials
/ Ceramic coatings
/ Corrosion resistance
/ Crystallization
/ Electrochemical corrosion
/ Fourier transforms
/ Hydrogen
/ Hydroxyapatite
/ Magnesium base alloys
/ Magnetron sputtering
/ Mechanical properties
/ Precipitation hardening
/ Protective coatings
/ Radio frequency
/ Silica glass
/ Substrates
/ Surgical implants
/ Transplants & implants
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Electrochemical and In Vitro Biological Evaluation of Bio-Active Coatings Deposited by Magnetron Sputtering onto Biocompatible Mg-0.8Ca Alloy
by
Antoniac, Aurora
, Forna, Norin
, Antoniac, Iulian
, Bița, Ana-Iulia
, Stan, George E.
, Miculescu, Marian
, Constantin, Bujor
, Leonat, Lucia
in
Alloys
/ Biocompatibility
/ Biodegradability
/ Biodegradable materials
/ Biodegradation
/ Biomedical materials
/ Ceramic coatings
/ Corrosion resistance
/ Crystallization
/ Electrochemical corrosion
/ Fourier transforms
/ Hydrogen
/ Hydroxyapatite
/ Magnesium base alloys
/ Magnetron sputtering
/ Mechanical properties
/ Precipitation hardening
/ Protective coatings
/ Radio frequency
/ Silica glass
/ Substrates
/ Surgical implants
/ Transplants & implants
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Electrochemical and In Vitro Biological Evaluation of Bio-Active Coatings Deposited by Magnetron Sputtering onto Biocompatible Mg-0.8Ca Alloy
by
Antoniac, Aurora
, Forna, Norin
, Antoniac, Iulian
, Bița, Ana-Iulia
, Stan, George E.
, Miculescu, Marian
, Constantin, Bujor
, Leonat, Lucia
in
Alloys
/ Biocompatibility
/ Biodegradability
/ Biodegradable materials
/ Biodegradation
/ Biomedical materials
/ Ceramic coatings
/ Corrosion resistance
/ Crystallization
/ Electrochemical corrosion
/ Fourier transforms
/ Hydrogen
/ Hydroxyapatite
/ Magnesium base alloys
/ Magnetron sputtering
/ Mechanical properties
/ Precipitation hardening
/ Protective coatings
/ Radio frequency
/ Silica glass
/ Substrates
/ Surgical implants
/ Transplants & implants
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Electrochemical and In Vitro Biological Evaluation of Bio-Active Coatings Deposited by Magnetron Sputtering onto Biocompatible Mg-0.8Ca Alloy
Journal Article
Electrochemical and In Vitro Biological Evaluation of Bio-Active Coatings Deposited by Magnetron Sputtering onto Biocompatible Mg-0.8Ca Alloy
2022
Request Book From Autostore
and Choose the Collection Method
Overview
The use of resorbable magnesium alloys in the design of implants represents a new direction in the healthcare domain. Two main research avenues are currently explored for developing or improving metallic biomaterials: (i) increase of their corrosion resistance by designed compositional and structural modifications, and (ii) functionalization of their surfaces by coating with ceramic or polymeric layers. The main objective of this work was to comparatively assess bio-functional coatings (i.e., highly-crystallized hydroxyapatite and silica-rich glass) deposited by radio-frequency magnetron sputtering (RF-MS) on a biodegradable Mg-0.8Ca alloy (0.8 wt.% of Ca). After probing their morphology (by scanning electron microscopy) and structure (by Fourier transform infrared spectroscopy and grazing incidence X-ray diffraction), the corrosion resistance of the RF-MS coated Mg-0.8Ca substrates was electrochemically tested (in synthetic biological media with different degrees of biomimicry), and their cytocompatibility was assessed in osteoblast and fibroblast cell cultures. By collective assessment, the most promising performances, in terms of mass loss (~7% after 12 days), hydrogen release rate (~6 mL/cm2 after 12 days), electrochemical corrosion parameters and cytocompatibility, were obtained for the crystalline HA coating.
Publisher
MDPI AG,MDPI
Subject
/ Hydrogen
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.