MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22
Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22
Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22
Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22
Journal Article

Design of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns per ACI CODE-440.11-22

2023
Request Book From Autostore and Choose the Collection Method
Overview
This paper is an attempt at a better understanding of design provisions of ACI CODE-440.11-22, building code for the design of glass fiber-reinforced polymer (GFRP)-reinforced concrete (RC) columns. Sway and a non-sway column examples originally designed with steel reinforcement were redesigned using GFRP longitudinal bars and ties as per provisions of ACI CODE-440.11-22 to analyze the effect of changing reinforcement type. Columns were designed with both low-modulus ([E.sub.f] = 6500 ksi), and high-modulus ([E.sub.f] = 8700 ksi) GFRP bars. A parametric study was carried out by varying the concrete compressive strength, the cross-section aspect ratio, and the resultant load eccentricity. GFRP-RC columns require larger cross-section dimensions and more reinforcement area than steel-RC columns irrespective of the GFRP elastic modulus when subjected to the same demand. The concrete strength has a significant effect on the dimensions of GFRP-RC columns, and rectangular sections were found to be more efficient than square sections with the same gross concrete area in the presence of moment. GFRP-RC columns subject to high eccentricity loads take advantage of GFRP tensile properties and, thus, are more efficient. Keywords: building code; concrete columns; eccentricity; glass fiber-reinforced polymer (GFRP) reinforcement.