Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Lifetime and Failure Characteristics of Pt/Ne Hollow Cathode Lamps Used as Calibration Sources for UV Space Instruments
by
Osterman, Steven
, Cunningham, Nathaniel
, Keyes, Charles D. (Tony)
, Sansonetti, Craig J.
, Penton, Steven V.
, Kerber, Florian
, Rosa, Michael R.
, Nave, Gillian
, Beasley, Matthew
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Lifetime and Failure Characteristics of Pt/Ne Hollow Cathode Lamps Used as Calibration Sources for UV Space Instruments
by
Osterman, Steven
, Cunningham, Nathaniel
, Keyes, Charles D. (Tony)
, Sansonetti, Craig J.
, Penton, Steven V.
, Kerber, Florian
, Rosa, Michael R.
, Nave, Gillian
, Beasley, Matthew
in
2012
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Lifetime and Failure Characteristics of Pt/Ne Hollow Cathode Lamps Used as Calibration Sources for UV Space Instruments
by
Osterman, Steven
, Cunningham, Nathaniel
, Keyes, Charles D. (Tony)
, Sansonetti, Craig J.
, Penton, Steven V.
, Kerber, Florian
, Rosa, Michael R.
, Nave, Gillian
, Beasley, Matthew
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Lifetime and Failure Characteristics of Pt/Ne Hollow Cathode Lamps Used as Calibration Sources for UV Space Instruments
Journal Article
Lifetime and Failure Characteristics of Pt/Ne Hollow Cathode Lamps Used as Calibration Sources for UV Space Instruments
2012
Request Book From Autostore
and Choose the Collection Method
Overview
ABSTRACT We report accelerated aging tests on three Pt/Ne lamps from the same manufacturing run as lamps installed on the Cosmic Origins Spectrograph (COS). One lamp was aged in air at the National Institute of Standards and Technology (NIST) at a current of 10 mA and 50% duty cycle (30 s on, 30 s off) until failure. Two other lamps were aged by the COS instrument development team in a vacuum chamber. Initial radiometrically calibrated spectra were taken of all three lamps at NIST. Calibrated spectra of the air-aged lamp were taken after 206, 500, 778, 783 and 897 hr of operation. Spectra of the vacuum-aged lamps were taken after 500 hr for both lamps, and after 1000 hr for one of the lamps. During vacuum aging, the lamp voltage, photometric stability and temperature were monitored. All three lamps lasted for over 900 hr (100,000 cycles) when run at 10 mA, sufficient for 10-12 years of operation on COS. The total output dropped by less than 15% over 500 hr, with short-term repeatability within a few percent. We recommend that future space operation of these lamps include the lamp voltage in the telemetry as a diagnostic for the lamp aging.
Publisher
University of Chicago Press
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.