MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Analysis of the effect of active power threshold on dynamic metering of energy meters
Analysis of the effect of active power threshold on dynamic metering of energy meters
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Analysis of the effect of active power threshold on dynamic metering of energy meters
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Analysis of the effect of active power threshold on dynamic metering of energy meters
Analysis of the effect of active power threshold on dynamic metering of energy meters

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Analysis of the effect of active power threshold on dynamic metering of energy meters
Analysis of the effect of active power threshold on dynamic metering of energy meters
Journal Article

Analysis of the effect of active power threshold on dynamic metering of energy meters

2024
Request Book From Autostore and Choose the Collection Method
Overview
With the high proportion of new energy and power electronic equipment access in the construction of new power systems, the dynamic volatility of the grid signal is stronger, which poses a serious challenge to accurate metering. To address this problem, this paper starts with the analysis of the electric energy metering algorithm principle. Firstly, the measurement characteristics of the Moving average algorithm and the Non-overlapping algorithm are compared. Secondly, on the basis of studying the steady-state signal metrology power metering error of the two algorithms when there is an active power threshold, the metrology ability of the two algorithms to dynamic signal is further analyzed. The conclusion is drawn that the threshold will cause the metrology power metering error of the moving average algorithm. The non-overlapping algorithm has a certain probability of power metering error. Finally, by designing different input signals, the moving average and non-overlapping algorithms are tested, respectively, to verify the effectiveness of the analysis. The research results of this paper can provide ideas for the research and analysis of dynamic metering algorithms of energy meters.