MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Design and simulation analysis of electric needleless syringe
Design and simulation analysis of electric needleless syringe
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Design and simulation analysis of electric needleless syringe
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Design and simulation analysis of electric needleless syringe
Design and simulation analysis of electric needleless syringe

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Design and simulation analysis of electric needleless syringe
Design and simulation analysis of electric needleless syringe
Journal Article

Design and simulation analysis of electric needleless syringe

2023
Request Book From Autostore and Choose the Collection Method
Overview
A new design of a needleless syringe based on a moving-coil electromagnetic linear actuator drive is proposed to address the problems of the uncontrollable driving force and bulky structure commonly found in current commercial needleless syringes. The structural parameters of the moving-coil electromagnetic linear actuator with the electromagnetic driving force at different current strengths are obtained using the finite element analysis method. The results of jet stagnation pressure and jet velocity were obtained by MATLAB numerical calculation and CFD jet simulation. The process of 0.1 ml drug diffusion under the skin at a current size of 40 A was simulated. The results show that the jet stagnation pressure at the nozzle is 32 MPa, the jet velocity is 246 m/s, and the jet diffusion depth reaches 15 mm under the maximum driving force condition. The output electromagnetic force of the moving-coil electromagnetic linear actuator in this scheme is proportional to the current’s magnitude, and the actuator’s small size allows it to be used as a driving component of a hand-held needleless syringe.