Research on Airflow Parameters in the Generator Floor of a Pumped Storage Power Station During Summer condition
by
Tian, Wei
, Gao, Jiayi
, Xu, Desheng
, Li, Junmei
, Zhao, Hengxuan
, Li, Yanfeng
in
Air conditioning
/ Air flow
/ Air temperature
/ Energy consumption
/ Generator Floor
/ On-site Tests
/ Parameters
/ Power plants
/ Pumped storage
/ Pumped Storage Power Station
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Research on Airflow Parameters in the Generator Floor of a Pumped Storage Power Station During Summer condition
by
Tian, Wei
, Gao, Jiayi
, Xu, Desheng
, Li, Junmei
, Zhao, Hengxuan
, Li, Yanfeng
in
Air conditioning
/ Air flow
/ Air temperature
/ Energy consumption
/ Generator Floor
/ On-site Tests
/ Parameters
/ Power plants
/ Pumped storage
/ Pumped Storage Power Station
2025
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Research on Airflow Parameters in the Generator Floor of a Pumped Storage Power Station During Summer condition
by
Tian, Wei
, Gao, Jiayi
, Xu, Desheng
, Li, Junmei
, Zhao, Hengxuan
, Li, Yanfeng
in
Air conditioning
/ Air flow
/ Air temperature
/ Energy consumption
/ Generator Floor
/ On-site Tests
/ Parameters
/ Power plants
/ Pumped storage
/ Pumped Storage Power Station
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Research on Airflow Parameters in the Generator Floor of a Pumped Storage Power Station During Summer condition
Journal Article
Research on Airflow Parameters in the Generator Floor of a Pumped Storage Power Station During Summer condition
2025
Request Book From Autostore
and Choose the Collection Method
Overview
This paper investigates airflow parameters for a pumped storage power station in Shandong. Continuous measurement was conducted for air temperature and humidity parameters at a height of 1.5m in the generator floor during summer. During test, three units operated and a supply air volume of 150,000 m 3 /h with 20.5°C and 90% RH was sent to generator floor. The results indicate that air parameters upstream and downstream of the generator floor satisfied the requirements of ≤30°C and ≤75%RH. Since the air temperature in the generator floor consistently remained below 24°C, which was significantly lower than the specified values, it is necessary to implement energy-saving control strategies for the air conditioning system to reduce operational energy consumption. The findings could provide reference for the energy-efficient design of the ventilation and air conditioning system in the main plant.