Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Connection between TPO geomembrane and concrete perimeter joints of Jurong Pumped Storage Power Station Process testing
by
Xie, Changshui
, Wang, Shiyun
, Lu, Qiang
, Wan, Miao
in
Power plants
/ Pumped storage
/ Seepage
/ Stainless steels
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Connection between TPO geomembrane and concrete perimeter joints of Jurong Pumped Storage Power Station Process testing
by
Xie, Changshui
, Wang, Shiyun
, Lu, Qiang
, Wan, Miao
in
Power plants
/ Pumped storage
/ Seepage
/ Stainless steels
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Connection between TPO geomembrane and concrete perimeter joints of Jurong Pumped Storage Power Station Process testing
Journal Article
Connection between TPO geomembrane and concrete perimeter joints of Jurong Pumped Storage Power Station Process testing
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Through the production test of the connection between TPO geomembrane and concrete peripheral joints, it is clear that angle steel has greater stiffness and better compaction anchoring effect than flat steel, while the anchoring structure type remains unchanged; When the horizontal tension force does not exceed 10kN, the deformation of the geomembrane at the anchoring point of the stainless steel chemical bolt is less than 50 mm, which does not exceed the coverage range of the SR anti-seepage rubber strip, verifying that the anchoring structure type is reasonable and effective.
Publisher
IOP Publishing
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.