Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins
by
Tacey, Mark
, Choong, Ee Siang
, Courtot, Tegan
, Peng, Sammi
, Lye, Jessica
, Foroudi, Farshad
, Joon, Daryl Lim
, Chao, Michael
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins
by
Tacey, Mark
, Choong, Ee Siang
, Courtot, Tegan
, Peng, Sammi
, Lye, Jessica
, Foroudi, Farshad
, Joon, Daryl Lim
, Chao, Michael
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins
Journal Article
Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Systematic and random errors in radiation dose delivery necessitate the use of planning target volume (PTV) margins to ensure adequate clinical target volume (CTV) treatment. Advances in magnetic resonance-guided radiation therapy (MRgRT) have enabled improved imaging with possible margin reduction; however, the optimal PTV margins remain uncertain. This study aimed to evaluate the adaptive radiotherapy component of intra-fractional prostate movement in MRgRT for prostate cancer (PCa) patients and determine appropriate PTV margins.
This study retrospectively analyzed 18 PCa patients treated using a 1.5 T MR-Linac. The initial fusion MR and verification MR scans were registered offline to assess prostate displacement between the two scans in the anterior-posterior (AP), left-right (LR) and superior-inferior (SI) directions. Random and systematic errors were calculated, and the PTV margins were determined using the Van Herk formula.
The average time between MR scans was 22 min (range 9-54 min) compared to an average beam-on time of 6 min (range 2-11 min). Mean and standard deviation of translational displacement was 1.2 ± 0.9 mm in the AP, 0.6 ± 0.5 mm in the LR, and 1.1 ± 0.8 mm in the SI directions. The calculated PTV margin was 3.2 mm in AP, 1.7 mm in LR, and 3.2 mm in SI directions. There was an observed trend of increased prostate motion with increased treatment duration.
MRgRT facilitates PTV margin reduction for PCa; however, our findings suggest that increased on-couch time may be associated with greater prostate motion. Future studies with larger patient cohorts and real-time motion monitoring are recommended to optimise margin strategies.