Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
New Generation Cardiac Contractility Modulation Device—Filling the Gap in Heart Failure Treatment
by
Florea, Roxana
, Micu, Sorin
, Tint, Diana
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
New Generation Cardiac Contractility Modulation Device—Filling the Gap in Heart Failure Treatment
by
Florea, Roxana
, Micu, Sorin
, Tint, Diana
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
New Generation Cardiac Contractility Modulation Device—Filling the Gap in Heart Failure Treatment
Journal Article
New Generation Cardiac Contractility Modulation Device—Filling the Gap in Heart Failure Treatment
2019
Request Book From Autostore
and Choose the Collection Method
Overview
(1) Background: Heart failure (HF) is a major cause of morbidity and mortality throughout the world. Despite substantial progress in its prevention and treatment, mortality rates remain high. Device therapy for HF mainly includes cardiac resynchronization therapy (CRT) and the use of an implantable cardioverter-defibrillator (ICD). Recently, however, a new device therapy—cardiac contractility modulation (CCM)—became available. (2) Aim: The purpose of this study is to present a first case-series of patients with different clinical patterns of HF with a reduced ejection fraction (HFrEF), supported with the newest generation of CCM devices. (3) Methods and results: Five patients with a left ventricular ejection fraction (LVEF) ≤ 35% and a New York Heart Association (NYHA) class ≥ III were supported with CCM OPTIMIZER® SMART IPGCCMX10 at our clinic. The patients had a median age of 67 ± 8.03 years (47–80) and were all males—four with ischemic etiology dilated cardiomyopathy. In two cases, CCM was added on top of CRT (non-responders), and, in one patient, CCM was delivered during persistent atrial fibrillation (AF). After 6 months of follow-up, the LVEF increased from 25.4 ± 6.8% to 27 ± 9%, and the six-minute walk distance increased from 310 ± 65.1 m to 466 ± 23.6 m. One patient died 47 days after device implantation. (4) Conclusion: CCM therapy provided with the new model OPTIMIZER® SMART IPG CCMX10 is safe, feasible, and applicable to a wide range of patients with HF.
Publisher
MDPI
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.