MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
Journal Article

Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation

2021
Request Book From Autostore and Choose the Collection Method
Overview
Hygrothermal simulations can be used as a reliable tool in analysing moisture performance. For an efficient analysis, it is important to appropriately select the wall orientation in the simulations. ASHRAE 160 recommends to using orientation with highest amount of annual wind-driven rain (WDR) and the orientation with the least annual solar radiation. The objective of this work was to identify the orientation which leads to the worst moisture performance of different wall assemblies under historical climate in different Canadian cities. Four cardinal orientations (North, East, South, and West) and orientation receiving the highest amount of annual WDR (Default) were tested in this study. The simulations were carried out assuming three scenarios of moisture loads for four different wood-frame (2×6 wood stud) wall systems that differ by their claddings: brick, fibreboard, stucco, and vinyl. With an assumption of no WDR, north facing wall always leads to the worst moisture performance. In the presence of WDR, with and without water source, default orientation leads to the worst moisture performance with few exceptions. As default orientation was based on total sum of WDR, it sometimes may not lead to worst performance and hence hourly distribution of WDR should be taken into consideration.
Publisher
IOP Publishing

MBRLCatalogueRelatedBooks