Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
by
Defo, Maurice
, Lacasse, Michael A
, Aggarwal, Chetan
, Ge, Hua
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
by
Defo, Maurice
, Lacasse, Michael A
, Aggarwal, Chetan
, Ge, Hua
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
Journal Article
Identifying the critical orientation of wood-frame walls in assessing moisture risks using hygrothermal simulation
2021
Request Book From Autostore
and Choose the Collection Method
Overview
Hygrothermal simulations can be used as a reliable tool in analysing moisture performance. For an efficient analysis, it is important to appropriately select the wall orientation in the simulations. ASHRAE 160 recommends to using orientation with highest amount of annual wind-driven rain (WDR) and the orientation with the least annual solar radiation. The objective of this work was to identify the orientation which leads to the worst moisture performance of different wall assemblies under historical climate in different Canadian cities. Four cardinal orientations (North, East, South, and West) and orientation receiving the highest amount of annual WDR (Default) were tested in this study. The simulations were carried out assuming three scenarios of moisture loads for four different wood-frame (2×6 wood stud) wall systems that differ by their claddings: brick, fibreboard, stucco, and vinyl. With an assumption of no WDR, north facing wall always leads to the worst moisture performance. In the presence of WDR, with and without water source, default orientation leads to the worst moisture performance with few exceptions. As default orientation was based on total sum of WDR, it sometimes may not lead to worst performance and hence hourly distribution of WDR should be taken into consideration.