Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Inertial solution for high-pressure-difference pulse-decay measurement through microporous media
by
Tian, Zhiguo
, Wang, Yue
, Zhang, Shaohua
, Zhang, Duzhou
, Wang, Moran
, Zhou, Gang
in
Asymptotic methods
/ Circular tubes
/ Compressibility
/ Compressibility effects
/ Decay
/ Flow paths
/ Flow rates
/ Flow velocity
/ Flow-density-speed relationships
/ Fluid flow
/ High pressure
/ Incompressible flow
/ Inertia
/ Internal flow
/ JFM Rapids
/ Mass flow rate
/ Navier-Stokes equations
/ Permeability
/ Perturbation
/ Pressure
/ Pressure effects
/ Reynolds number
/ Rheology
/ Unsteady flow
/ Viscosity
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Inertial solution for high-pressure-difference pulse-decay measurement through microporous media
by
Tian, Zhiguo
, Wang, Yue
, Zhang, Shaohua
, Zhang, Duzhou
, Wang, Moran
, Zhou, Gang
in
Asymptotic methods
/ Circular tubes
/ Compressibility
/ Compressibility effects
/ Decay
/ Flow paths
/ Flow rates
/ Flow velocity
/ Flow-density-speed relationships
/ Fluid flow
/ High pressure
/ Incompressible flow
/ Inertia
/ Internal flow
/ JFM Rapids
/ Mass flow rate
/ Navier-Stokes equations
/ Permeability
/ Perturbation
/ Pressure
/ Pressure effects
/ Reynolds number
/ Rheology
/ Unsteady flow
/ Viscosity
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Inertial solution for high-pressure-difference pulse-decay measurement through microporous media
by
Tian, Zhiguo
, Wang, Yue
, Zhang, Shaohua
, Zhang, Duzhou
, Wang, Moran
, Zhou, Gang
in
Asymptotic methods
/ Circular tubes
/ Compressibility
/ Compressibility effects
/ Decay
/ Flow paths
/ Flow rates
/ Flow velocity
/ Flow-density-speed relationships
/ Fluid flow
/ High pressure
/ Incompressible flow
/ Inertia
/ Internal flow
/ JFM Rapids
/ Mass flow rate
/ Navier-Stokes equations
/ Permeability
/ Perturbation
/ Pressure
/ Pressure effects
/ Reynolds number
/ Rheology
/ Unsteady flow
/ Viscosity
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Inertial solution for high-pressure-difference pulse-decay measurement through microporous media
Journal Article
Inertial solution for high-pressure-difference pulse-decay measurement through microporous media
2023
Request Book From Autostore
and Choose the Collection Method
Overview
We present a theoretical asymptotic solution for high-speed transient flow through microporous media in this work by addressing the inertia effect in the high-pressure-difference pulse-decay process. The capillaric model is adopted, in which a bundle of straight circular tubes with a high length–radius ratio is used to represent the internal flow paths of microporous media so that the flow is described by a simplified incompressible Navier–Stokes equation based on the mean density, capturing the major characteristics of mass flow rate. By order-of-magnitude analysis and asymptotic perturbation, the inertial solution with its dimensionless criterion for the high-pressure-difference pulse-decay process is derived. To be compared with experimental data, the theoretical solution involves all three related effects, including the inertia effect, the slippage effect and the compressibility effect. A self-built experimental platform is therefore established to measure the permeability of microporous media by both pulse-decay and steady-state methods to validate the theoretical solution. The results indicate that the relative difference between two methods is less than 30 % even for permeability at as low as $48.2$ nD $(10^{-21}\\,{\\rm m}^2)$, and the present theoretical solution can accurately capture the inertia effect in the high-pressure-difference pulse-decay process, which significantly accelerates the measurements for ultra-low-permeability samples.
Publisher
Cambridge University Press
Subject
This website uses cookies to ensure you get the best experience on our website.