MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis
Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis
Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis
Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis
Journal Article

Stress Distribution in a Mandibular Kennedy Class I with Bilateral Implant-Assisted Removable Partial Denture: A Finite Element Analysis

2025
Request Book From Autostore and Choose the Collection Method
Overview
Objectives: This study evaluated the dental and alveolar bone stress distribution of a mandibular Kennedy Class I restored with a bilateral implant-assisted removable partial denture (IARPD) compared with a conventional removable partial denture (CRPD) through the application of finite element analysis (FEA). Methods: Kennedy Class I plaster models were made, including teeth from the lower left first premolar and lower right canine. The models were scanned, resin-based replicated and digitized. Using Solidworks software, internal hexagonal implants (10 mm × 4 mm) were virtually placed at the level of the first molars. Each model was grouped into a unit, and a load of 200 N was applied, simulating masticatory forces. Von Mises stress distributions were calculated via FEA for the vertical, diagonal and combined forces. Results: In the IARPD, the stress generated in the alveolar bone by the vertical (4.2 Mpa), diagonal (12.2 MPa) and combined forces (12.3 MPa) was lower than that of the CRPD (7 MPa, 26.3 MPa and 32 MPa, respectively). Similarly, at the lower central incisor, the IARPD generated less stress than the CRPD due to the action of the vertical, diagonal and combined forces. Conclusions: Our preliminary data suggest that bilateral implant placement may result in less stress on bone and teeth during rehabilitation with a Kennedy Class I IARPD, with different orientations of the forces applied.