MbrlCatalogueTitleDetail

Do you wish to reserve the book?
An alternative to the use of lead for patient treatment shielding in superficial radiotherapy
An alternative to the use of lead for patient treatment shielding in superficial radiotherapy
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
An alternative to the use of lead for patient treatment shielding in superficial radiotherapy
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
An alternative to the use of lead for patient treatment shielding in superficial radiotherapy
An alternative to the use of lead for patient treatment shielding in superficial radiotherapy

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
An alternative to the use of lead for patient treatment shielding in superficial radiotherapy
An alternative to the use of lead for patient treatment shielding in superficial radiotherapy
Journal Article

An alternative to the use of lead for patient treatment shielding in superficial radiotherapy

2021
Request Book From Autostore and Choose the Collection Method
Overview
Lead shielding is commonly used in the delivery of superficial radiotherapy albeit that the toxicity of this substance is of concern. The feasibility of using a non-toxic alternative, AttenuFlex™, is assessed using Xstrahl and Sensus treatment units. A series of lead and AttenuFlex™ circular cut outs and applicators were used with superficial beams (1.0–8.5 mm Al HVL) to measure percentage depth dose (PDD), output factors (OF) and surface dose correction factors (DCF). X-ray transmission for each material was determined for each beam quality. For these measurements an Advanced Markus chamber either embedded within a virtual water phantom (PDD, OF, transmission) or placed on the surface of the phantom with entrance window downstream (DCF), was used. The depth of the phantom is 10 cm for PDD and surface OF measurements. DCF(t) measurements were obtained with underlying lead or AttenuFlex™ at depth t = 0.1–10 cm. Additionally, using EBT3 film fluorescent surface doses, to non-target tissue, due to underlying lead or AttenuFlex™ were compared. PDDs and OFs for both materials were within ± 1%. Lead and AttenuFlex™ transmission differences were clinically acceptable, all transmission values were < 5% and non-target doses were comparable. The variation of DCF(t) for lead and AttenuFlex™ exhibit a minima for all beams. In the minima region energy and applicator dependent differences between DCF(lead) and DCF(AttenuFlex™) are observed. These differences do not preclude the use of AttenuFlex™ as an alternative to lead in superficial therapy.
Publisher
Springer Nature B.V