Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Microtomography on the ANATOMIX beamline at Synchrotron SOLEIL
by
Engblom, C
, Scheel, M
, Polack, F
, Cauchon, G
, King, A
, Gohon, Y
, Cerato, M
, Weitkamp, T
, Daniel, G
, Moreno, T
, Giorgetta, JL
, Langlois, F
, Menneglier, C
, Le Roux, V
, Desjardins, K
, Rivard, C
, Carcy, A
, Perrin, J
in
Microtomography
/ Phase contrast
/ Physics
/ Spatial resolution
/ Synchrotrons
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Microtomography on the ANATOMIX beamline at Synchrotron SOLEIL
by
Engblom, C
, Scheel, M
, Polack, F
, Cauchon, G
, King, A
, Gohon, Y
, Cerato, M
, Weitkamp, T
, Daniel, G
, Moreno, T
, Giorgetta, JL
, Langlois, F
, Menneglier, C
, Le Roux, V
, Desjardins, K
, Rivard, C
, Carcy, A
, Perrin, J
in
Microtomography
/ Phase contrast
/ Physics
/ Spatial resolution
/ Synchrotrons
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Microtomography on the ANATOMIX beamline at Synchrotron SOLEIL
by
Engblom, C
, Scheel, M
, Polack, F
, Cauchon, G
, King, A
, Gohon, Y
, Cerato, M
, Weitkamp, T
, Daniel, G
, Moreno, T
, Giorgetta, JL
, Langlois, F
, Menneglier, C
, Le Roux, V
, Desjardins, K
, Rivard, C
, Carcy, A
, Perrin, J
in
Microtomography
/ Phase contrast
/ Physics
/ Spatial resolution
/ Synchrotrons
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Microtomography on the ANATOMIX beamline at Synchrotron SOLEIL
Journal Article
Microtomography on the ANATOMIX beamline at Synchrotron SOLEIL
2022
Request Book From Autostore
and Choose the Collection Method
Overview
The ANATOMIX beamline at Synchrotron SOLEIL, operational since 2018, is dedicated to hard X-ray full-field tomography techniques. Operating in a range of photon energies from approximately 5 to 50 keV, it offers both parallel-beam projection microtomography, in absorption and phase contrast, and nanotomography using a zone-plate transmission X-ray microscope. With these methods, the beamline covers a range of spatial resolution from 20 nm to 20 µm, expressed in terms of useful pixel size. The variable beam size of up to 40 mm allows users to image large objects. Here we describe the microtomography instrumentation of the beamline.
Publisher
IOP Publishing
Subject
This website uses cookies to ensure you get the best experience on our website.