Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Cooling challenges in a NEG-coated vacuum chamber of a light source
by
Zamani, F
, Danaeifard, A
, Motlagh, S Talebi
, Saeidi, F
, Rahighi, J
in
Brazed joints
/ Cooling
/ Copper base alloys
/ Filler metals
/ Light sources
/ Physics
/ Pipes
/ Synchrotron radiation
/ Synchrotrons
/ Thermal conductivity
/ Vacuum chambers
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Cooling challenges in a NEG-coated vacuum chamber of a light source
by
Zamani, F
, Danaeifard, A
, Motlagh, S Talebi
, Saeidi, F
, Rahighi, J
in
Brazed joints
/ Cooling
/ Copper base alloys
/ Filler metals
/ Light sources
/ Physics
/ Pipes
/ Synchrotron radiation
/ Synchrotrons
/ Thermal conductivity
/ Vacuum chambers
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Cooling challenges in a NEG-coated vacuum chamber of a light source
by
Zamani, F
, Danaeifard, A
, Motlagh, S Talebi
, Saeidi, F
, Rahighi, J
in
Brazed joints
/ Cooling
/ Copper base alloys
/ Filler metals
/ Light sources
/ Physics
/ Pipes
/ Synchrotron radiation
/ Synchrotrons
/ Thermal conductivity
/ Vacuum chambers
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Cooling challenges in a NEG-coated vacuum chamber of a light source
Journal Article
Cooling challenges in a NEG-coated vacuum chamber of a light source
2023
Request Book From Autostore
and Choose the Collection Method
Overview
In a Light Source, unused synchrotron radiation is being distributed along the walls of the chambers. Due to the small conductance of the chambers, vacuum pumping will be based on the distributed concept, and then non-evaporable getter (NEG) coating is extensively used. The vacuum chambers are made of copper alloys tube, and cooling circuits are welded to the chamber to remove the heat load from the radiation generated. Filler metal creates a brazed joint between the water-cooling pipe and the vacuum chamber body. The thermal conductivity of the fillers is less than the vacuum chamber body. On the other hand, the velocity of the water in the cooling pipe is a critical parameter in thermal calculations that must be taken into account. So, in this paper, we study and investigate the effects of the filler metal and the cooling water velocity on cooling the NEG-coated chambers.
Publisher
IOP Publishing
Subject
This website uses cookies to ensure you get the best experience on our website.