MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings
Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings
Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings
Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings
Journal Article

Range of applicability of real mode superposition approximation method for seismic response calculation of non-classically damped industrial buildings

2022
Request Book From Autostore and Choose the Collection Method
Overview
An industrial building is a non-classically damped system due to the different damping properties of the primary structure and equipment. The objective of this paper is to quantify the range of applicability of the real model superposition approximation method to the seismic response calculation of industrial buildings. The analysis using lumped mass-and-shear spring models indicates that for the equipment-to-structure frequency ratios γf > 1.1 or γf < 0.9, the non-classical damping effect is limited, and the real mode superposition approximation method provides accurate estimates. For 0.9 < γf < 1.1, the system may have a pair of closely spaced frequency modes, and the non-zero off-diagonal damping terms have a non-negligible effect on the damping ratios and mode shape vectors of these modes. For 0.9 < γf < 1.1 and the equipment-to-structure mass ratios γm < 0.07, the real mode superposition approximation method results in large errors, while the approximation method can provide an accurate estimation for 0.9 < γf <1.1 and γm > 0.07. Furthermore, extensive parametric analyses are conducted, where both steel structures and reinforced concrete structures with equipment with various damping ratios are considered. Finally, the finite element analysis of a five-story industrial building is adopted to validate the proposed range of applicability.