Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Fuzzy Logic Approach to Dissolved Gas Analysis for Power Transformer Failure Index and Fault Identification
by
Suwanasri, Thanapong
, Poonnoy, Nitchamon
, Suwanasri, Cattareeya
in
dissolved gas analysis
/ Duval triangle
/ IEC 60599
/ key gas method
/ power transformer
/ total dissolved combustible gases
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Fuzzy Logic Approach to Dissolved Gas Analysis for Power Transformer Failure Index and Fault Identification
by
Suwanasri, Thanapong
, Poonnoy, Nitchamon
, Suwanasri, Cattareeya
in
dissolved gas analysis
/ Duval triangle
/ IEC 60599
/ key gas method
/ power transformer
/ total dissolved combustible gases
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Fuzzy Logic Approach to Dissolved Gas Analysis for Power Transformer Failure Index and Fault Identification
by
Suwanasri, Thanapong
, Poonnoy, Nitchamon
, Suwanasri, Cattareeya
in
dissolved gas analysis
/ Duval triangle
/ IEC 60599
/ key gas method
/ power transformer
/ total dissolved combustible gases
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Fuzzy Logic Approach to Dissolved Gas Analysis for Power Transformer Failure Index and Fault Identification
Journal Article
Fuzzy Logic Approach to Dissolved Gas Analysis for Power Transformer Failure Index and Fault Identification
2021
Request Book From Autostore
and Choose the Collection Method
Overview
This research focuses on problem identification due to faults in power transformers during operation by using dissolved gas analysis such as key gas, IEC ratio, Duval triangle techniques, and fuzzy logic approaches. Then, the condition of the power transformer is evaluated in terms of the percentage of failure index and internal fault determination. Fuzzy logic with the key gas approach was used to calculate the failure index and identify problems inside the power transformer. At the same time, the IEC three-gas ratio and Duval triangle are subsequently applied to confirm the problems in different failure types covering all possibilities inside the power transformer. After that, the fuzzy logic system was applied and validated with DGA results of 244 transformers as reference cases with satisfactory accuracy. Two transformers were evaluated and practically confirmed by the investigation results of an un-tanked power transformer. Finally, the DGA results of a total of 224 transformers were further evaluated by the fuzzy logic system. This fuzzy logic is a smart, accurate tool for automatically identifying faults occurring within transformers. Finally, the recommendation of maintenance strategy and time interval is proposed for effective planning to minimize the catastrophic damage, which could occur with the power transformer and its network.
Publisher
MDPI AG
This website uses cookies to ensure you get the best experience on our website.