Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Amplified Fluorescent Aptasensor for Ochratoxin A Assay Based on Graphene Oxide and RecJf Exonuclease
by
Xiong, Dehui
, Ma, Changbei
, Zhao, Han
, Yan, Ying
in
fluorescence
/ graphene oxide
/ ochratoxin A
/ RecJf exonuclease
/ signal amplification
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Amplified Fluorescent Aptasensor for Ochratoxin A Assay Based on Graphene Oxide and RecJf Exonuclease
by
Xiong, Dehui
, Ma, Changbei
, Zhao, Han
, Yan, Ying
in
fluorescence
/ graphene oxide
/ ochratoxin A
/ RecJf exonuclease
/ signal amplification
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Amplified Fluorescent Aptasensor for Ochratoxin A Assay Based on Graphene Oxide and RecJf Exonuclease
Journal Article
Amplified Fluorescent Aptasensor for Ochratoxin A Assay Based on Graphene Oxide and RecJf Exonuclease
2020
Request Book From Autostore
and Choose the Collection Method
Overview
In this study, we developed an aptamer-based fluorescent sensing platform for the detection of ochratoxin A (OTA) based on RecJf exonuclease-assisted signal amplification and interaction between graphene oxide (GO) and the OTA aptamer (OTA-apt). After optimizing the experimental conditions, the present aptamer-based sensing system can exhibit excellent fluorescent response in the OTA assay, with a limit of detection of 0.07 ng/mL. In addition to signal amplification, this strategy is also highly specific for other interfering toxins. Furthermore, this aptasensor can be reliably used for assessing red wine samples spiked with different OTA concentrations (2.4, 6 and 20 ng/mL). The proposed assay plays an important role in the field of food safety and can be transformed for detecting other toxins by replacing the sequence that recognizes the aptamer.
Publisher
MDPI,MDPI AG
Subject
This website uses cookies to ensure you get the best experience on our website.