MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry
Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry
Journal Article

Conventional Hepatic Volumetry May Lead to Inaccurate Segmental Yttrium-90 Radiation Dosimetry

2021
Request Book From Autostore and Choose the Collection Method
Overview
ObjectiveTo compare radioembolization treatment zone volumes from mapping cone beam CT (CBCT) versus planning CT/MRI and to model their impact on dosimetry.MethodsY90 cases were retrospectively identified in which intra-procedural CBCT angiograms were performed. Segmental and lobar treatment zone volumes were calculated with semi-automated contouring using Couinaud venous anatomy (planning CT/MRI) or tumor angiosome enhancement (CBCT). Differences were compared with a Wilcoxon signed-rank test. Treatment zone-specific differences in segmental volumes by volumetric method were also calculated and used to model differences in delivered dose using medical internal radiation dosimetry (MIRD) at 200 and 120 Gy targets. Anatomic, pathologic, and technical factors likely affecting segmental volumes by volumetric method were evaluated.ResultsForty segmental and 48 lobar CBCT angiograms and corresponding planning CT/MRI scans were included. Median Couinaud- and CBCT-derived segmental volumes were 281 and 243 mL, respectively (p = 0.005). Differences between Couinaud and CBCT lobar volumes (right, left) were not significant (p = 0.24, p = 0.07). Couinaud overestimated segmental volumes in 28 cases by a median of 98 mL (83%) and underestimated in 12 cases by median 69 mL (20%). At a 200 Gy dose target, Couinaud estimates produced median delivered doses of 367 and 160 Gy in these 28 and 12 cases. At a 120 Gy target, Couinaud produced doses of 220 and 96 Gy. Proximal vs. distal microcatheter positioning, variant arterial anatomy, and tumor location on or near segmental watersheds were leading factors linked to volumetric differences.ConclusionUse of CBCT-based volumetry may allow more accurate, personalized dosimetry for segmental Y90 radioembolization.
Publisher
Springer Nature B.V