Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Preparation, Evaluation and Field Application of Thermally Induced Crosslinked Polymer Gel Leakage Plugging Agent
by
Djouonkep, Lesly Dasilva Wandji
, Lv, Junxian
, Xie, Binqiang
, Qiu, Hengbin
, Chen, Jindong
in
Crosslinking
/ Drilling
/ High pressure
/ High temperature
/ Leakage
/ Low pressure
/ Low temperature
/ Low temperature resistance
/ Plugging
/ Polyacrylamide
/ Polymer gels
/ Polymers
/ Pressure
/ Pressure filters
/ Room temperature
/ Sand beds
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Preparation, Evaluation and Field Application of Thermally Induced Crosslinked Polymer Gel Leakage Plugging Agent
by
Djouonkep, Lesly Dasilva Wandji
, Lv, Junxian
, Xie, Binqiang
, Qiu, Hengbin
, Chen, Jindong
in
Crosslinking
/ Drilling
/ High pressure
/ High temperature
/ Leakage
/ Low pressure
/ Low temperature
/ Low temperature resistance
/ Plugging
/ Polyacrylamide
/ Polymer gels
/ Polymers
/ Pressure
/ Pressure filters
/ Room temperature
/ Sand beds
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Preparation, Evaluation and Field Application of Thermally Induced Crosslinked Polymer Gel Leakage Plugging Agent
by
Djouonkep, Lesly Dasilva Wandji
, Lv, Junxian
, Xie, Binqiang
, Qiu, Hengbin
, Chen, Jindong
in
Crosslinking
/ Drilling
/ High pressure
/ High temperature
/ Leakage
/ Low pressure
/ Low temperature
/ Low temperature resistance
/ Plugging
/ Polyacrylamide
/ Polymer gels
/ Polymers
/ Pressure
/ Pressure filters
/ Room temperature
/ Sand beds
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Preparation, Evaluation and Field Application of Thermally Induced Crosslinked Polymer Gel Leakage Plugging Agent
Journal Article
Preparation, Evaluation and Field Application of Thermally Induced Crosslinked Polymer Gel Leakage Plugging Agent
2024
Request Book From Autostore
and Choose the Collection Method
Overview
Addressing the complex issue of lost circulation in drilling operations is crucial as it increases nonproductive time and costs. Conventional gel plugging materials often exhibit low temperature resistance, poor pumpability, and low pressure-bearing capacity. To overcome the limitations, a self-made polymer (HSA) was initially synthesized and mixed with two crosslinker agents (MBA/PEI) at room temperature to induce a new type of high-temperature-resistant and pressure-resistant polymer gel agent (HSA-G). Investigating the gel strength and plugging capacity, the vertical inverted tube observation, 71-type high-temperature and high-pressure (HTHP) instruments, and high-pressure filter with varying fracture cracks (3–5 mm) were employed. HSA-G demonstrated excellent gelation strength for 4–5 h at 140 °C, while retaining more than 57% of its gel strength after aging at 140 °C for 144 h, which is 3 times higher than the commercially available hydrolyzed polyacrylamide (HPAM + PEI). The excellent performance was attributed to the synergy between PEI-MBA, which induces tight-crosslinked interconnected structure within HSA-G, mitigating fluid losses to only 72 mL compared to 194 mL for HPAM-G, under 8.5 MPa in the HTHP sand bed at 140 °C. In the fracture leakage simulations using a 5 mm crack performed at 6 MPa at room temperature, the filtration loss of HSA-G is 300 mL, almost half that of HPAM-G, showcasing its superior plugging and high-pressure bearing performance. In conclusion, HSA-G has not only demonstrated operational effectiveness in reducing downtime costs and fluid losses but can also temporally replace cement plugging to prevent reservoir contamination in alignment with environmentally friendly practices.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.