Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A signal quality assessment–based ECG waveform delineation method used for wearable monitoring systems
by
Zuo Feng
, Li, Yongqin
, Liang, Wei
, Xie Jialing
, Yin Changlin
, Li, Peng
, Gong Yushun
, Wang, Juan
in
Algorithms
/ Bandpass filters
/ Cardiovascular diseases
/ Delineation
/ Diagnosis
/ EKG
/ Electrocardiography
/ Electrodes
/ Heart rate
/ Monitoring
/ Movement
/ Neural networks
/ Quality assessment
/ Quality control
/ Segments
/ Signal classification
/ Signal quality
/ Silver chloride
/ Telemedicine
/ Waveforms
/ Wearable computers
/ Wearable technology
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A signal quality assessment–based ECG waveform delineation method used for wearable monitoring systems
by
Zuo Feng
, Li, Yongqin
, Liang, Wei
, Xie Jialing
, Yin Changlin
, Li, Peng
, Gong Yushun
, Wang, Juan
in
Algorithms
/ Bandpass filters
/ Cardiovascular diseases
/ Delineation
/ Diagnosis
/ EKG
/ Electrocardiography
/ Electrodes
/ Heart rate
/ Monitoring
/ Movement
/ Neural networks
/ Quality assessment
/ Quality control
/ Segments
/ Signal classification
/ Signal quality
/ Silver chloride
/ Telemedicine
/ Waveforms
/ Wearable computers
/ Wearable technology
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A signal quality assessment–based ECG waveform delineation method used for wearable monitoring systems
by
Zuo Feng
, Li, Yongqin
, Liang, Wei
, Xie Jialing
, Yin Changlin
, Li, Peng
, Gong Yushun
, Wang, Juan
in
Algorithms
/ Bandpass filters
/ Cardiovascular diseases
/ Delineation
/ Diagnosis
/ EKG
/ Electrocardiography
/ Electrodes
/ Heart rate
/ Monitoring
/ Movement
/ Neural networks
/ Quality assessment
/ Quality control
/ Segments
/ Signal classification
/ Signal quality
/ Silver chloride
/ Telemedicine
/ Waveforms
/ Wearable computers
/ Wearable technology
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A signal quality assessment–based ECG waveform delineation method used for wearable monitoring systems
Journal Article
A signal quality assessment–based ECG waveform delineation method used for wearable monitoring systems
2021
Request Book From Autostore
and Choose the Collection Method
Overview
Identifying transient and nonpersistent abnormal electrocardiogram (ECG) waveforms by continuously monitoring the high-risk populations is of great importance for the diagnosis, treatment, and prevention of cardiovascular diseases. In recent years, fabric electrodes have been widely used in wearable devices because of their non-irritating properties and better comfort than traditional AgCl electrodes. However, the motion noise caused by the relative movement between the fabric electrodes and skin affects the quality of ECGs and reduces the accuracy of diagnosis. Therefore, delineating the ECG waveforms that are recorded from wearable devices with varying levels of noise is still challenging. In this study, a signal quality assessment (SQA)–based ECG waveform delineation method that is used for wearable systems was developed. The ECG signal was first preprocessed by a bandpass filter. Five indices, including the multiscale nonlinear amplitude statistical distribution (adSQI1, adSQI2), the proportion of energy-related to T wave (ptSQI), and heart rates computed from R waves and T waves (rHR and tHR, respectively), were then calculated from the preprocessed ECG signal. The signals were classified as good, acceptable, and unacceptable ECGs by combining these indices through the use of a neural network. Subsequently, the R waves or/and T waves were identified for the corresponding feature interpretations based on the SQA results. ECGs that were recorded from the chest belts from 29 volunteers at different activity statuses were divided into 4-s segments. A total of 7133 manually labeled segments were used to derive (4985 segments) and validate (2148 segments) the algorithm. The adSQI1, adSQI2, tHR, and rHR characteristics were significantly different among the good, acceptable, and unacceptable ECGs. The ptSQI value was considerably higher in the good ECGs than in the acceptable and unacceptable ECGs. The ECG segments of different quality levels were classified with an accuracy of 96.74% by using the proposed SQA method. The R waves and T waves were identified with accuracies of 99.95% and 99.57%, respectively, for segments that were classified as acceptable and/or good. The SQA-based ECG waveform delineation method can perform reliable analysis and has the potential to be applied in wearable ECG systems for the early diagnosis and prevention of cardiovascular diseases.