Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Influence of indoor airflow on airborne disease transmission in a classroom
by
Li, Ri
, Zabihi, Mojtaba
, Brinkerhoff, Joshua
in
Aerosols
/ Air flow
/ Air quality
/ Building Construction and Design
/ Classrooms
/ Computational fluid dynamics
/ Cover Article
/ Design
/ Disease control
/ Disease spread
/ Disease transmission
/ Engineering
/ Engineering Thermodynamics
/ Flow distribution
/ Fluid dynamics
/ Heat and Mass Transfer
/ Hydrodynamics
/ Monitoring/Environmental Analysis
/ Outdoor air quality
/ Particle size
/ Two phase flow
/ Ventilation
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Influence of indoor airflow on airborne disease transmission in a classroom
by
Li, Ri
, Zabihi, Mojtaba
, Brinkerhoff, Joshua
in
Aerosols
/ Air flow
/ Air quality
/ Building Construction and Design
/ Classrooms
/ Computational fluid dynamics
/ Cover Article
/ Design
/ Disease control
/ Disease spread
/ Disease transmission
/ Engineering
/ Engineering Thermodynamics
/ Flow distribution
/ Fluid dynamics
/ Heat and Mass Transfer
/ Hydrodynamics
/ Monitoring/Environmental Analysis
/ Outdoor air quality
/ Particle size
/ Two phase flow
/ Ventilation
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Influence of indoor airflow on airborne disease transmission in a classroom
by
Li, Ri
, Zabihi, Mojtaba
, Brinkerhoff, Joshua
in
Aerosols
/ Air flow
/ Air quality
/ Building Construction and Design
/ Classrooms
/ Computational fluid dynamics
/ Cover Article
/ Design
/ Disease control
/ Disease spread
/ Disease transmission
/ Engineering
/ Engineering Thermodynamics
/ Flow distribution
/ Fluid dynamics
/ Heat and Mass Transfer
/ Hydrodynamics
/ Monitoring/Environmental Analysis
/ Outdoor air quality
/ Particle size
/ Two phase flow
/ Ventilation
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Influence of indoor airflow on airborne disease transmission in a classroom
Journal Article
Influence of indoor airflow on airborne disease transmission in a classroom
2024
Request Book From Autostore
and Choose the Collection Method
Overview
It has been widely accepted that the most effective way to mitigate airborne disease transmission in an indoor space is to increase the ventilation airflow, measured in air change per hour (ACH). However, increasing ACH did not effectively prevent the spread of COVID-19. To better understand the role of ACH and airflow large-scale patterns, a comprehensive fully transient computational fluid dynamics (CFD) simulation of two-phase flows based on a discrete phase model (DPM) was performed in a university classroom setting with people present. The investigations encompass various particle sizes, ventilation layouts, and flow rates. The findings demonstrated that the particle size threshold at which particles are deemed airborne is highly influenced by the background flow strength and large-scale flow pattern, ranging from 5 µm to 10 µm in the cases investigated. The effects of occupants are significant and must be precisely accounted for in respiratory particle transport studies. An enhanced ventilation design (UFAD-CDR) for university classrooms is introduced that places a premium on mitigating airborne disease spread. Compared to the baseline design at the same ACH, this design successfully reduced the maximum number density of respiratory particles by up to 85%. A novel airflow-related parameter, Horizontality, is introduced to quantify and connect the large-scale airflow pattern with indoor aerosol transport. This underscores that ACH alone cannot ensure or regulate air quality. In addition to the necessary ACH for air exchange, minimizing horizontal bulk motion is essential for reducing aerosol transmissibility within the room.
Publisher
Tsinghua University Press,Springer Nature B.V