MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links
Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links
Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links
Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links
Journal Article

Mechanical Behavior of a Double-Column Self-Centering Pier Fused with Shear Links

2019
Request Book From Autostore and Choose the Collection Method
Overview
A double-column self-centering pier fused with shear links is a novel structure developed to reduce residual deformation and facilitate post-earthquake repair. With this novel structure, the seismic resilience of bridges can be improved, and the reliability of lifeline infrastructure can be ensured. This paper presents the proposed pier configuration and investigates the mechanical behavior of the pier. A simplified finite element model is established to develop the lateral force-displacement relationship under cyclic loading. Additionally, a theoretical model based on the matrix displacement method and the virtual work principle is proposed to calculate the lateral force-displacement skeleton curve. The rationality and reliability of the theoretical model are validated by the satisfactory agreement observed between the numerical and theoretical results. Furthermore, a series of parametric analyses are conducted to discuss the effects of key parameters. The outcomes of this work can serve as a reference for further development of the design method for the innovated pier.