MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment
Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment
Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment
Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment
Journal Article

Continuous-Input Continuous-Output Current Buck-Boost DC/DC Converters for Renewable Energy Applications: Modelling and Performance Assessment

2019
Request Book From Autostore and Choose the Collection Method
Overview
Stand-alone/grid connected renewable energy systems (RESs) require direct current (DC)/DC converters with continuous-input continuous-output current capabilities as maximum power point tracking (MPPT) converters. The continuous-input current feature minimizes the extracted power ripples while the continuous-output current offers non-pulsating power to the storage batteries/DC-link. CUK, D1 and D2 DC/DC converters are highly competitive candidates for this task especially because they share similar low-component count and functionality. Although these converters are of high resemblance, their performance assessment has not been previously compared. In this paper, a detailed comparison between the previously mentioned converters is carried out as several aspects should be addressed, mainly the converter tracking efficiency, conversion efficiency, inductor loss, system modelling, transient and steady-state performance. First, average model and dynamic analysis of the three converters are derived. Then, D1 and D2 small signal analysis in voltage-fed-mode is originated and compared to that of CUK in order to address the nature of converters’ response to small system changes. Finally, the effect of converters’ inductance variation on their performance is studied using rigorous simulation and experimental implementation under varying operating conditions. The assessment finally revels that D1 converter achieves the best overall efficiency with minimal inductor value.