Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Enhanced Transformer Overcurrent Protection via Oil Temperature Acceleration
by
Liu, Qingguo
, Sun, Jiahang
, Zhou, Shanshan
, Mei, Nuonan
, Wang, Zheng
in
Hearing protection
/ inverse-time overcurrent protection
/ minor transformer failure
/ parameter optimization and setting
/ Research methodology
/ transformer oil temperature
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Enhanced Transformer Overcurrent Protection via Oil Temperature Acceleration
by
Liu, Qingguo
, Sun, Jiahang
, Zhou, Shanshan
, Mei, Nuonan
, Wang, Zheng
in
Hearing protection
/ inverse-time overcurrent protection
/ minor transformer failure
/ parameter optimization and setting
/ Research methodology
/ transformer oil temperature
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Enhanced Transformer Overcurrent Protection via Oil Temperature Acceleration
by
Liu, Qingguo
, Sun, Jiahang
, Zhou, Shanshan
, Mei, Nuonan
, Wang, Zheng
in
Hearing protection
/ inverse-time overcurrent protection
/ minor transformer failure
/ parameter optimization and setting
/ Research methodology
/ transformer oil temperature
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Enhanced Transformer Overcurrent Protection via Oil Temperature Acceleration
Journal Article
Enhanced Transformer Overcurrent Protection via Oil Temperature Acceleration
2024
Request Book From Autostore
and Choose the Collection Method
Overview
When a transformer is in a long-term heavy load operation state, the oil temperature reaches the alarm temperature; if a slight fault occurs inside the transformer, traditional inverse time current protection and other protections that react to phase current may not operate due to insufficient sensitivity or they may operate for too long. Based on this, this article proposes a new principle of accelerating inverse time overcurrent protection based on transformer oil temperature. The proposed method uses transformer oil temperature to accelerate the action time of traditional inverse-time overcurrent protection, then introduces the transformer oil temperature factor and acceleration index to optimize the inverse time characteristic curve, and establishes a mathematical model to optimize the adjustment for the complexity of adjustment of the protection action equation and the risk of mismatch of the protection after the acceleration of oil temperature. The existing theoretical analysis and simulation verification results show that the proposed new overcurrent protection scheme based on the transformer oil temperature acceleration inverse time can effectively improve the protection of the rapidity and sensitivity, providing a new research idea for the combination of non-electrical and electrical quantity protection.
Publisher
MDPI AG
This website uses cookies to ensure you get the best experience on our website.