Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique
by
Mani, Karthick Raj
, Basu, Saumen
, Das, K. J. Maria
, Ahmed, Sharif
, Un Nabi, Md Rashid
, Sengupta, Ashim Kumar
, Sumon, Mostafa Aziz
, Bhuiyan, Md Anisuzzaman
, Haque, Kh Anamul
in
Asymmetry
/ bilateral breast
/ Brain
/ Breast
/ Chest
/ Divergence
/ Esophagus
/ Fatalities
/ Irradiation
/ Mastectomy
/ mono isocenter
/ Patients
/ Photons
/ Radiation therapy
/ Separation
/ Spots
/ Sternum
/ synchronous bilateral breast
/ Toxicity
/ Weighting
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique
by
Mani, Karthick Raj
, Basu, Saumen
, Das, K. J. Maria
, Ahmed, Sharif
, Un Nabi, Md Rashid
, Sengupta, Ashim Kumar
, Sumon, Mostafa Aziz
, Bhuiyan, Md Anisuzzaman
, Haque, Kh Anamul
in
Asymmetry
/ bilateral breast
/ Brain
/ Breast
/ Chest
/ Divergence
/ Esophagus
/ Fatalities
/ Irradiation
/ Mastectomy
/ mono isocenter
/ Patients
/ Photons
/ Radiation therapy
/ Separation
/ Spots
/ Sternum
/ synchronous bilateral breast
/ Toxicity
/ Weighting
2017
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique
by
Mani, Karthick Raj
, Basu, Saumen
, Das, K. J. Maria
, Ahmed, Sharif
, Un Nabi, Md Rashid
, Sengupta, Ashim Kumar
, Sumon, Mostafa Aziz
, Bhuiyan, Md Anisuzzaman
, Haque, Kh Anamul
in
Asymmetry
/ bilateral breast
/ Brain
/ Breast
/ Chest
/ Divergence
/ Esophagus
/ Fatalities
/ Irradiation
/ Mastectomy
/ mono isocenter
/ Patients
/ Photons
/ Radiation therapy
/ Separation
/ Spots
/ Sternum
/ synchronous bilateral breast
/ Toxicity
/ Weighting
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique
Journal Article
Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique
2017
Request Book From Autostore
and Choose the Collection Method
Overview
Objective: The purpose of this study is to demonstrate the synchronous bilateral breast irradiation radiotherapy technique using a single isocenter. Materials and Methods: Six patients of synchronous bilateral breast were treated with single isocenter technique from February 2011 to June 2016. All the patients underwent a CT-simulation using appropriate positioning device. Target volumes and critical structures like heart, lung, esophagus, thyroid, etc., were delineated slice by slice in the CT data. An isocenter was placed above the sternum on the skin and both medial tangential and lateral tangential of the breast / chest wall were created using asymmetrical jaws to avoid the beam divergence through the lung and heart. The field weighting were adjusted manually to obtain a homogenous dose distribution. The planning objectives were to deliver uniform doses around the target and keep the doses to the organ at risk within the permissible limit. The beam energy of 6 MV or combination of 6 MV and 15 MV photons were used in the tangential fields according to the tangential separation. Boluses were used for all the mastectomy patients to increase the doses on the chest wall. In addition to that enhanced dynamic wedge and field in field technique were also used to obtain a homogenous distribution around the target volume and reduce the hot spots. The isocenter was just kept on the skin, such that the beam junctions will be overlapped only on the air just above the sternum. Acute toxicity during the treatment and late toxicity were recorded during the patient’s follow-up. Results: During the radiotherapy treatment follow-up there were no acute skin reactions in the field junctions, but one patient had grade 1 esophagitis and two patients had grade 2 skin reactions in the chest wall. With a median follow-up of 38.5 months (range: 8 - 49 months), no patients had a local recurrence, but one patients with triple negative disease had a distant metastases in brain and died after 28 months. Conclusions: We were able to successfully treat the synchronous bilateral breast using single isocenter radiotherapy while keeping the lung and heart doses within the acceptable dose limits. During the treatment follow-up there were no symptoms of acute skin reactions in the field junction.
This website uses cookies to ensure you get the best experience on our website.