In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
by
Li-Hong Yao Jun-Jie Wang Charles Shang Ping Jiang Lei Lin Hai-Tao Sun Lu Liu Hao Liu Di He Rui-Jie Yang
in
Brachytherapy; Computer Simulation; Phantom; Radiometry; Thermoluminescent Dosimetry
/ Dosimetry
/ MC模拟
/ Original
/ Radiation therapy
/ Seeds
/ Stents
/ TLD测量
/ 体外
/ 剂量学特性
/ 径向剂量分布
/ 支架
/ 放射性
/ 粒子
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
by
Li-Hong Yao Jun-Jie Wang Charles Shang Ping Jiang Lei Lin Hai-Tao Sun Lu Liu Hao Liu Di He Rui-Jie Yang
in
Brachytherapy; Computer Simulation; Phantom; Radiometry; Thermoluminescent Dosimetry
/ Dosimetry
/ MC模拟
/ Original
/ Radiation therapy
/ Seeds
/ Stents
/ TLD测量
/ 体外
/ 剂量学特性
/ 径向剂量分布
/ 支架
/ 放射性
/ 粒子
2017
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
by
Li-Hong Yao Jun-Jie Wang Charles Shang Ping Jiang Lei Lin Hai-Tao Sun Lu Liu Hao Liu Di He Rui-Jie Yang
in
Brachytherapy; Computer Simulation; Phantom; Radiometry; Thermoluminescent Dosimetry
/ Dosimetry
/ MC模拟
/ Original
/ Radiation therapy
/ Seeds
/ Stents
/ TLD测量
/ 体外
/ 剂量学特性
/ 径向剂量分布
/ 支架
/ 放射性
/ 粒子
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
Journal Article
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
2017
Request Book From Autostore
and Choose the Collection Method
Overview
Background: A novel radioactive ^125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths -- with different number as well as activities of ^125I seeds. Methods: The radiation dosimetry of three representative radioactive stent models was evaluated using a treatment planning system (TPS), thermoluminescent dosimeter (TLD) measurements, and Monte Carlo (MC) simulations. In the process of TPS calculation and TLD measurement, two different water-equivalent phantoms were designed to obtain cumulative radial dose distribution. Calibration procedures using TLD in the designed phantom were also conducted. MC simulations were performed using the Monte Carlo N-Particle extended version 2.5 general purpose code to calculate the radioactive stent's three-dimensional dose rate distribution in liquid water. Analysis of covariance was used to examine the factors influencing radial dose distribution of the radioactive stent. Results: The maximum reduction in cumulative radial dose was 26% when the seed activity changed from 0.5 mCi to 0,4 mCi for the same length of radioactive stents. The TLD's dose response in the range of 0-10 mGy irradiation by ^137Cs y-ray was linear: y = 182225x - 6651.9 (R2 = 0.99152; y is the irradiation dose in mGy, x is the TLDs' reading in nC). When TLDs were irradiated by different energy radiation sources to a dose of 1 mGy, reading of TLDs was different. Doses at a distance of 0.1 cm from the three stents' surface simulated by MC were 79, 93, and 97 Gy. Conclusions: TPS calculation, TLD measurement, and MC simulation were performed and were found to be in good agreement. Although the whole experiment was conducted in water-equivalent phantom, data in our evaluation may provide a theoretical basis for dosimetry for the clinical application.
Publisher
Lippincott Williams & Wilkins Ovid Technologies,Department of Radiation Oncology, Lynn Cancer Institute, Boca Raton, FL 33486, USA%Department of Computer Science and Engineering, University of Washington, Seattle, WA 98195, USA%LMAM, School of Mathematical Sciences, Peking University, Beijing 100871, China,Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China%Department of Physics, Florida Atlantic University, Boca Raton, FL 33431, USA,Medknow Publications & Media Pvt Ltd,Wolters Kluwer
This website uses cookies to ensure you get the best experience on our website.