MbrlCatalogueTitleDetail

Do you wish to reserve the book?
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds
Journal Article

In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive ^125I Seeds

2017
Request Book From Autostore and Choose the Collection Method
Overview
Background: A novel radioactive ^125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths -- with different number as well as activities of ^125I seeds. Methods: The radiation dosimetry of three representative radioactive stent models was evaluated using a treatment planning system (TPS), thermoluminescent dosimeter (TLD) measurements, and Monte Carlo (MC) simulations. In the process of TPS calculation and TLD measurement, two different water-equivalent phantoms were designed to obtain cumulative radial dose distribution. Calibration procedures using TLD in the designed phantom were also conducted. MC simulations were performed using the Monte Carlo N-Particle extended version 2.5 general purpose code to calculate the radioactive stent's three-dimensional dose rate distribution in liquid water. Analysis of covariance was used to examine the factors influencing radial dose distribution of the radioactive stent. Results: The maximum reduction in cumulative radial dose was 26% when the seed activity changed from 0.5 mCi to 0,4 mCi for the same length of radioactive stents. The TLD's dose response in the range of 0-10 mGy irradiation by ^137Cs y-ray was linear: y = 182225x - 6651.9 (R2 = 0.99152; y is the irradiation dose in mGy, x is the TLDs' reading in nC). When TLDs were irradiated by different energy radiation sources to a dose of 1 mGy, reading of TLDs was different. Doses at a distance of 0.1 cm from the three stents' surface simulated by MC were 79, 93, and 97 Gy. Conclusions: TPS calculation, TLD measurement, and MC simulation were performed and were found to be in good agreement. Although the whole experiment was conducted in water-equivalent phantom, data in our evaluation may provide a theoretical basis for dosimetry for the clinical application.
Publisher
Lippincott Williams & Wilkins Ovid Technologies,Department of Radiation Oncology, Lynn Cancer Institute, Boca Raton, FL 33486, USA%Department of Computer Science and Engineering, University of Washington, Seattle, WA 98195, USA%LMAM, School of Mathematical Sciences, Peking University, Beijing 100871, China,Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China%Department of Physics, Florida Atlantic University, Boca Raton, FL 33431, USA,Medknow Publications & Media Pvt Ltd,Wolters Kluwer