MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Journal Article

Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System

2019
Request Book From Autostore and Choose the Collection Method
Overview
Clinical trial data demonstrates improved glycemic control with hybrid close loop (HCL) insulin delivery systems, yet limited real-world data exists. Data from the inaugural cohort of patients initiating a HCL system (Medtronic MiniMed 670G, Medtronic Canada, Brampton, ON) at a university medical center was used to examine real-world utilization and glycemic control following a standardized implementation process. Data from 34 adult patients with type 1 diabetes were obtained from pump downloads at 4 time points: ( ) previous insulin pump, ( ) HCL in manual-mode, ( ) 2 weeks after HCL auto-mode transition, and ( ) 6 to 12 weeks after initiation of HCL. In-person training by certified diabetes educators was performed across 3 sessions with phone and electronic messaging following auto-mode start. Mean self-monitored blood glucose (SMBG) per day increased from 5.15 baseline to 6.49 at 6 to 12 weeks ( <.05) with 3.26 sensor calibrations per day. Time-in-auto-mode was 79.3% at 2 weeks and 72.3% at final follow-up, with 82% of patients spending >50% of time in auto-mode. There were 8.2 auto-mode exits over the final 14-day download. Time-in-target was 67.3% in manual-mode, 73.4% at 2 weeks ( = .09), and 71.7% by 6 to 12 weeks ( = .06). Hemoglobin A1c (HbA1c) decreased by 0.51% ( = .02), while total daily dose and % basal did not change. Patients with HbA1c <7.0% (53 mmol/mol) at baseline spent more time-in-target than those with HbA1c ≥7.0% (53 mmol/mol; 78.0% versus 67.5%) despite spending less time-in-auto-mode (66.5% versus 74.8%). These data illustrate real-world implementation of HCL technology using a structured education program within a major medical center. Overall benefit may vary based on baseline characteristics such as HbA1c. = certified diabetes educator; = hemoglobin A1c; = hybrid closed loop; = self-monitored blood glucose.