MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
Journal Article

Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study

2023
Request Book From Autostore and Choose the Collection Method
Overview
PurposeComminuted inferior patellar pole fractures are challenging injuries and require effective treatment due to the extension mechanism of the knee. This study aims to evaluate the outcome of above fractures treated with a modified technique of cerclage-wire-augmented separate vertical wiring (SVW) with cerclage wiring passed through the proximal patella.MethodsRetrospective analysis (1/2017–1/2020) were performed for patients that were treated with three SVWs through the posterior margin of proximal fragment and directly to the anterosuperior border of patella, combined with a cerclage wiring passed through the proximal patella. Patients who experienced comminuted inferior patellar pole fractures within 3 weeks were included, and the outcome was evaluated radiologically and clinically by Bostman score after a minimum of 12 months following surgery. Further evaluation included the operation time and complication rate.ResultsA total of 20 patients (10 males, 10 females) with a mean age of 54 ± 14.5 years (26–83 years) and a follow-up of 18.9 ± 6.6 months (12–36 months) were evaluated. The average operation time was 45.7 ± 8.8 min (30–60 min). At final follow-up, the average range of motion was 131.3° ± 3.5° (125°–135°), and the mean Bostman score was 29.4 ± 0.7 points (28–30) and graded excellent in all cases. Two patients experienced occasional giving way of the knee. Radiologically no loss of reduction, implant breakage, nonunion or skin irritation was observed.ConclusionsThe cerclage-wire-augmented SVW with cerclage wiring passed through the proximal patella appears to be a safe and simple technique which can effectively treat the comminuted inferior patellar pole fractures.