MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure
Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure
Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure
Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure
Journal Article

Seismic Performance and Optimization Design of a Post-Installed Elevator Shear Wall Structure

2023
Request Book From Autostore and Choose the Collection Method
Overview
Post-installed elevator projects have grown significantly in recent years in response to the problem of insufficient vertical traffic capacity in existing buildings, but research on the seismic performance of post-installed elevator structures has been relatively limited. This study takes a 26-story-frame shear wall structure as an example. The seismic response characteristics of this structure before and after the installation of elevators were analyzed. In order to optimize the design scheme of the post-installed elevator structure, this study further analyzed how factors such as the standard height of the elevator shaft frame, the elevator location, and the way the post-installed elevator is connected to the structure affect the seismic response of the elevator structure. The results show that the post-installed elevators have a small impact on the seismic performance of the existing building and can slightly reduce the seismic response of the structure. In addition, the stiffness of the elevator shaft will be reduced, and its seismic response will be slightly increased as the standard shaft height is increased, but the construction cost can be reduced. The installation location has a greater impact on the seismic response of the post-installed elevator. The seismic response of the post-installed elevator is minimal when it is arranged near the elevator shaft of the existing building.