MbrlCatalogueTitleDetail

Do you wish to reserve the book?
P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions
P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions
P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions
P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions
Journal Article

P-Delta Effects on Nonlinear Seismic Behavior of Steel Moment-Resisting Frame Structures Subjected to Near-Fault and Far-Fault Ground Motions

2022
Request Book From Autostore and Choose the Collection Method
Overview
This paper presents a comparison of P-Delta effects on the nonlinear seismic behavior of the steel moment-resisting frame structures (MRFs) subjected to near-fault and far-fault ground motions. The 3-, 9- and 20-story MRFs designed for the American SAC Phase II Steel Project are used as benchmark models. The 40 near-fault ground motions with large velocity pulses, as well as ten typical far-fault ground motions, are selected and scaled for the nonlinear time-history analysis. The P-Delta effect is quantified based on peak inter-story drift ratio (PIDR) demands. The displacement demands of the whole structure and the distortion of the structural components are compared and analyzed. It was found that, at each floor, the P-Delta effect under near-fault ground motions is more significant than that under the far-fault ground motions. The P-Delta effect under near-fault ground motions also increases more rapidly with decreasing structure height even for low-rise structures or low earthquake intensity. It was also found that the P-Delta effect cause the PIDR demands to increase by 10% for all three structures subjected to far-fault ground motions. In contrast, considering the P-Delta effect, the PIDR demands rapidly increase by 45% for the high-rise building subjected to near-fault ground motions. Note that the increasing PIDR demands occur at the weakest floor and with the stronger earthquake intensity. However, the P-Delta effect does not change the location of the weakest floor and the yield sequence of components. The seismic behaviors under far-fault and near-fault ground motions are significantly different, because near-fault ground motions not only have velocity pulse but also possibly trigger structural higher vibration modes. In addition, the P-Delta effect may change the distortion direction of the components so that the prediction of the structural collapse direction may be affected. In addition, it was found that if the structure’s period is near the pulse period, the P-Delta effect becomes more significant with the increase of earthquake intensity, and accordingly, it should not be ignored. Moreover, the P-Delta effect cannot be neglected either for the structures susceptible to near-fault ground motions, even if those structures are not tall or the earthquake intensity is not strong.