Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Monitoring and Assessment of Rehabilitation Progress on Range of Motion After Total Knee Replacement by Sensor-Based System
by
Liu, Yu-Yu
, Lai, Li-Ju
, Huang, Yo-Ping
, Hsu, Wei-Hsiu
, Lee, Mel S.
in
inertial measurement unit (imu)
/ range of motion (rom)
/ rehabilitation progress
/ total knee replacement (tkr)
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Monitoring and Assessment of Rehabilitation Progress on Range of Motion After Total Knee Replacement by Sensor-Based System
by
Liu, Yu-Yu
, Lai, Li-Ju
, Huang, Yo-Ping
, Hsu, Wei-Hsiu
, Lee, Mel S.
in
inertial measurement unit (imu)
/ range of motion (rom)
/ rehabilitation progress
/ total knee replacement (tkr)
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Monitoring and Assessment of Rehabilitation Progress on Range of Motion After Total Knee Replacement by Sensor-Based System
by
Liu, Yu-Yu
, Lai, Li-Ju
, Huang, Yo-Ping
, Hsu, Wei-Hsiu
, Lee, Mel S.
in
inertial measurement unit (imu)
/ range of motion (rom)
/ rehabilitation progress
/ total knee replacement (tkr)
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Monitoring and Assessment of Rehabilitation Progress on Range of Motion After Total Knee Replacement by Sensor-Based System
Journal Article
Monitoring and Assessment of Rehabilitation Progress on Range of Motion After Total Knee Replacement by Sensor-Based System
2020
Request Book From Autostore
and Choose the Collection Method
Overview
For total knee replacement (TKR) patients, rehabilitation after the surgery is key to regaining mobility. This study proposes a sensor-based system for effectively monitoring rehabilitation progress after TKR. The system comprises a hardware module consisting of the triaxial accelerometer and gyroscope, a microcontroller, and a Bluetooth module, and a software app for monitoring the motion of the knee joint. Three indices, namely the number of swings, the maximum knee flexion angle, and the duration of practice each time, were used as metrics to measure the knee rehabilitation progress. The proposed sensor device has advantages such as usability without spatiotemporal constraints and accuracy in monitoring the rehabilitation progress. The performance of the proposed system was compared with the measured range of motion of the Cybex isokinetic dynamometer (or Cybex) professional rehabilitation equipment, and the results revealed that the average absolute errors of the measured angles were between 1.65° and 3.27° for the TKR subjects, depending on the swing speed. Experimental results verified that the proposed system is effective and comparable with the professional equipment.
Publisher
MDPI,MDPI AG
This website uses cookies to ensure you get the best experience on our website.