Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
High Recharge Areas in the Choushui River Alluvial Fan (Taiwan) Assessed from Recharge Potential Analysis and Average Storage Variation Indexes
by
Chen, Yu-Wen
, Kuo, Yi-Ming
, Chang, Liang-Cheng
, Pan, Chen-Che
, Tu, Yu-Hsuan
, Tsai, Jui-Pin
in
Alluvial fans
/ average storage variation
/ Calibration
/ Entropy
/ Estimates
/ geographical information system
/ Glass fiber reinforced plastics
/ Ground-water quality
/ Groundwater
/ groundwater recharge potential
/ high recharge areas
/ Recharge areas
/ Rivers
/ simulated annealing
2015
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
High Recharge Areas in the Choushui River Alluvial Fan (Taiwan) Assessed from Recharge Potential Analysis and Average Storage Variation Indexes
by
Chen, Yu-Wen
, Kuo, Yi-Ming
, Chang, Liang-Cheng
, Pan, Chen-Che
, Tu, Yu-Hsuan
, Tsai, Jui-Pin
in
Alluvial fans
/ average storage variation
/ Calibration
/ Entropy
/ Estimates
/ geographical information system
/ Glass fiber reinforced plastics
/ Ground-water quality
/ Groundwater
/ groundwater recharge potential
/ high recharge areas
/ Recharge areas
/ Rivers
/ simulated annealing
2015
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
High Recharge Areas in the Choushui River Alluvial Fan (Taiwan) Assessed from Recharge Potential Analysis and Average Storage Variation Indexes
by
Chen, Yu-Wen
, Kuo, Yi-Ming
, Chang, Liang-Cheng
, Pan, Chen-Che
, Tu, Yu-Hsuan
, Tsai, Jui-Pin
in
Alluvial fans
/ average storage variation
/ Calibration
/ Entropy
/ Estimates
/ geographical information system
/ Glass fiber reinforced plastics
/ Ground-water quality
/ Groundwater
/ groundwater recharge potential
/ high recharge areas
/ Recharge areas
/ Rivers
/ simulated annealing
2015
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
High Recharge Areas in the Choushui River Alluvial Fan (Taiwan) Assessed from Recharge Potential Analysis and Average Storage Variation Indexes
Journal Article
High Recharge Areas in the Choushui River Alluvial Fan (Taiwan) Assessed from Recharge Potential Analysis and Average Storage Variation Indexes
2015
Request Book From Autostore
and Choose the Collection Method
Overview
High recharge areas significantly influence the groundwater quality and quantity in regional groundwater systems. Many studies have applied recharge potential analysis (RPA) to estimate groundwater recharge potential (GRP) and have delineated high recharge areas based on the estimated GRP. However, most of these studies define the RPA parameters with supposition, and this represents a major source of uncertainty for applying RPA. To objectively define the RPA parameter values without supposition, this study proposes a systematic method based on the theory of parameter identification. A surrogate variable, namely the average storage variation (ASV) index, is developed to calibrate the RPA parameters, because of the lack of direct GRP observations. The study results show that the correlations between the ASV indexes and computed GRP values improved from 0.67 before calibration to 0.85 after calibration, thus indicating that the calibrated RPA parameters represent the recharge characteristics of the study area well; these data also highlight how defining the RPA parameters with ASV indexes can help to improve the accuracy. The calibrated RPA parameters were used to estimate the GRP distribution of the study area, and the GRP values were graded into five levels. High and excellent level areas are defined as high recharge areas, which composed 7.92% of the study area. Overall, this study demonstrates that the developed approach can objectively define the RPA parameters and high recharge areas of the Choushui River alluvial fan, and the results should serve as valuable references for the Taiwanese government in their efforts to conserve the groundwater quality and quantity of the study area.
Publisher
MDPI AG
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.