Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Coracohumeral Distances and Correlation to Arm Rotation
by
LaPrade, Robert F.
, Millett, Peter J.
, Brunkhorst, John P.
, Giphart, J. Erik
2013
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Coracohumeral Distances and Correlation to Arm Rotation
by
LaPrade, Robert F.
, Millett, Peter J.
, Brunkhorst, John P.
, Giphart, J. Erik
2013
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Coracohumeral Distances and Correlation to Arm Rotation
2013
Request Book From Autostore
and Choose the Collection Method
Overview
Background:
Reduced coracohumeral distances have been reported to be associated with anterior shoulder disorders such as subscapularis tears, biceps tendon injuries, and leading edge supraspinatus tears.
Purpose:
To determine the variability in coracohumeral distance as a function of arm rotation in healthy male subjects. The null hypothesis was that no differences in coracohumeral distance would exist with respect to arm rotation.
Study Design:
Descriptive laboratory study.
Methods:
A total of 9 male participants who had full range of motion, strength, and no prior surgery or symptoms in their tested shoulders were enrolled in this institutional review board–approved study. Computed tomography scans of the shoulder were obtained for each subject. A dynamic biplane fluoroscopy system recorded internal and external shoulder rotation with the arm held in the neutral position. Three-dimensional reconstructions of each motion were generated, and the coracohumeral distance and coracoid index (lateral extension of the coracoid) were measured.
Results:
The mean coracohumeral distance in neutral rotation was 12.7 ± 2.1 mm. A significantly shorter minimum coracohumeral distance of 10.6 ± 1.8 mm was achieved (P = .001) at a mean glenohumeral joint internal rotation angle of 36.6° ± 19.2°. This corresponded to a reduction in coracohumeral distance of 16.4% (range, 6.6%-29.8%). The mean coracoid index was 14.2 ± 6.8 mm. A moderate correlation (R = −0.75) existed between the coracohumeral distance and coracoid index.
Conclusion:
Coracohumeral distance was reduced during internal rotation. Decreased coracohumeral distance was correlated with larger coracoid indices.
Clinical Relevance:
This study provides a reference value for coracohumeral distance in the healthy male population. Knowledge of how coracohumeral distance varies over the range of arm internal-external rotation may improve the clinical diagnosis and treatment plan for patients with anterior shoulder pathology, specifically subcoracoid impingement. Imaging of the coracohumeral distance during internal rotation with the hand at approximately midline should be considered to assess patients with anterior shoulder pain.
Publisher
SAGE Publications
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.