MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA
Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA
Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA
Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA
Journal Article

Mapping Tunneling-Induced Uneven Ground Subsidence Using Sentinel-1 SAR Interferometry: A Twin-Tunnel Case Study of Downtown Los Angeles, USA

2023
Request Book From Autostore and Choose the Collection Method
Overview
Synthetic Aperture Radar (SAR) interferometry is a formidable technique to monitor surface deformation with a millimeter detection resolution. This study applies the Persistent Scatter-Interferometric Synthetic Aperture Radar (PSInSARTM) technique to measure ground subsidence related to a twin-tunnel excavation in downtown Los Angeles, USA. The PSInSARTM technique is suitable for urban settings because urban areas have strong reflectors. The twin tunnels in downtown Los Angeles were excavated beneath a densely urbanized area with variable overburden depths. In practice, tunneling-induced ground settlement is dominantly vertical. The vertical deformation rate in this study is derived by combining Line of Sight (LOS) deformation velocities obtained from SAR images from both ascending and descending satellite orbits. Local and uneven settlements up to approximately 12 mm/year along the tunnel alignment are observed within the allowable threshold. No severe damages to aboveground structures were reported. Furthermore, ground movements mapped one year before tunnel construction indicate that no concentrated ground settlements pre-existed. A Machine Learning (ML)-based permutation feature importance method is used for a parametric study to identify dominant factors associated with the twin-tunneling induced uneven ground subsidence. Six parameters are selected to conduct the parametric study, including overburden thickness, i.e., the thickness of artificial fill and alluvium soils above the tunnel springline, the distance between the two tunnel centerlines, the depth to the tunnel springline, building height, the distance to the tunnel, and groundwater level. Results of the parametric analysis indicate that overburden thickness, i.e., the thickness of artificial fill and alluvium soils above the tunnel springline, is the dominant contributing factor, followed by the distance between tunnel centerlines, depth to the tunnel springline, and building height. Two parameters, the distance to the tunnel, and the groundwater level, play lesser essential roles than others. In addition, the geological profile provides comprehension of unevenly distributed ground settlements, which are geologically sensitive and more concentrated in areas with thick artificial fill and alluvium soils, low tunnel depth, and high groundwater levels.